Comparative evaluation of left ventricular mass regression after aortic valve replacement: a prospective randomized analysis
Open Access
- 13 October 2011
- journal article
- research article
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 6 (1) , 136
Abstract
We assessed the hemodynamic performance of various prostheses and the clinical outcomes after aortic valve replacement, in different age groups. One-hundred-and-twenty patients with isolated aortic valve stenosis were included in this prospective randomized randomised trial and allocated in three age-groups to receive either pulmonary autograft (PA, n = 20) or mechanical prosthesis (MP, Edwards Mira n = 20) in group 1 (age < 55 years), either stentless bioprosthesis (CE Prima Plus n = 20) or MP (Edwards Mira n = 20) in group 2 (age 55-75 years) and either stentless (CE Prima Plus n = 20) or stented bioprosthesis (CE Perimount n = 20) in group 3 (age > 75). Clinical outcomes and hemodynamic performance were evaluated at discharge, six months and one year. In group 1, patients with PA had significantly lower mean gradients than the MP (2.6 vs. 10.9 mmHg, p = 0.0005) with comparable left ventricular mass regression (LVMR). Morbidity included 1 stroke in the PA population and 1 gastrointestinal bleeding in the MP subgroup. In group 2, mean gradients did not differ significantly between both populations (7.0 vs. 8.9 mmHg, p = 0.81). The rate of LVMR and EF were comparable at 12 months; each group with one mortality. Morbidity included 1 stroke and 1 gastrointestinal bleeding in the stentless and 3 bleeding complications in the MP group. In group 3, mean gradients did not differ significantly (7.8 vs 6.5 mmHg, p = 0.06). Postoperative EF and LVMR were comparable. There were 3 deaths in the stented group and no mortality in the stentless group. Morbidity included 1 endocarditis and 1 stroke in the stentless compared to 1 endocarditis, 1 stroke and one pulmonary embolism in the stented group. Clinical outcomes justify valve replacement with either valve substitute in the respective age groups. The PA hemodynamically outperformed the MPs. Stentless valves however, did not demonstrate significantly superior hemodynamics or outcomes in comparison to stented bioprosthesis or MPs.Keywords
This publication has 17 references indexed in Scilit:
- Are stentless valves hemodynamically superior to stented valves? A prospective randomized trialThe Annals of Thoracic Surgery, 2002
- Clinical outcomes and indicators of normalization of left ventricular dimensions after Ross procedure in children.2001
- Normalization of left ventricular dimensions after ross operation with aortic annular reductionThe Annals of Thoracic Surgery, 1999
- Long-term outcome after biologic versus mechanical aortic valve replacement in 841 patientsThe Journal of Thoracic and Cardiovascular Surgery, 1999
- Extent and pattern of regression of left ventricular hypertrophy in patients with small size carbomedics aortic valvesThe Journal of Thoracic and Cardiovascular Surgery, 1997
- Effects of Valve Substitute on Changes in Left Ventricular Function and Hypertrophy After Aortic Valve ReplacementThe Annals of Thoracic Surgery, 1996
- Up to thirty-year survival after aortic valve replacement in the small aortic rootThe Annals of Thoracic Surgery, 1995
- Asymptomatic ventricular arrhythmias and mortility risk in subjects withs with left ventricular hypertrophyJACC, 1993
- Left ventricular myocardial structure in aortic valve disease before, intermediate, and late after aortic valve replacement.Circulation, 1989
- Time course of regression of left ventricular hypertrophy after aortic valve replacement.Circulation, 1988