Technique for Drilling Instrument Monitoring Electrical Conductivity in Pediatric Cervical Spine Screw Insertion: A Preliminary Report
- 1 October 2009
- journal article
- spine
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 29 (7) , 760-764
Abstract
Background To detail a technique of assisted screw placement in pediatric patients with cervical spine disorders. The use of a recently produced wireless electronic freehand drilling instrument is documented. Methods We performed fixation of the cervical spine using different screws in 5 consecutive patients with various cervical spine disorders (posttraumatic, neoplastic or metabolic). Clinical and radiologic features of all cases are reported. The surgical technique is described. Results Twenty-six cervical screws (lateral mass, pars, and/or laminar) were placed with the use of the same pedicle screw pilot hole preparation device, and by the same surgical team. The average age of this patient group was 13.4 years (range: 6 to 16 y). Average follow-up was 10 months (range: 5 to 14 mo). All screws were inserted after the correct trajectory was identified. No breaches were detected. No screw failure was encountered. However, 8 of 26 (30.8%) screws were, on average, 1.3 mm longer that expected (range: 0.5 to 2.4 mm). None of the patients developed neurologic or vascular complications as a result of screw placement. Conclusions Cervical screws placement, although safe, is not free of complications: neurovascular injuries, dural tears, and paraplegia have been described. The use of a wireless electronic handheld pedicle screw pilot hole preparation instrument is a useful tool in the armamentarium of the spinal surgeon dealing with patients with complex spinal deformities or difficult anatomy. Our experience outlines the applicability of this technique at different cervical levels. However, this device is not satisfactory in predicting the length of the screws. The device should be modified or a preoperative computed tomography scan should be used to estimate safe the length of the screws. Level of Evidence Level IV (case series).Keywords
This publication has 24 references indexed in Scilit:
- Segmental Pedicle Screwing for Idiopathic Scoliosis Using Computer-assisted SurgeryJournal of Spinal Disorders & Techniques, 2008
- Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidanceEuropean Spine Journal, 2007
- Electrical conductivity measurement: a new technique to detect iatrogenic initial pedicle perforationEuropean Spine Journal, 2007
- Radiation Exposure During Pedicle Screw Placement in Adolescent Idiopathic Scoliosis: Is Fluoroscopy Safe?Spine, 2006
- Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric dataEuropean Spine Journal, 2006
- Safety and Efficacy of C2 Pedicle Screws Placed With Anatomic and Lateral C-Arm GuidanceSpine, 2006
- Nationwide survey on complications of spine surgery in JapanJournal of Orthopaedic Science, 2004
- Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patientsEuropean Spine Journal, 2000
- Safety and Accuracy of Transarticular Screw Fixation C1-C2 Using an Aiming DeviceSpine, 1998
- Osseous Bridging of Lumbar Intertransverse Processes After TraumaSpine, 1992