Effects of interpupillary distance on stereoacuity: the Frisby Davis distance stereotest versus a 3-dimensional distance stereotest
Authors:
- 5 July 2013
- journal article
- research article
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 57 (5) , 486-492
Abstract
To evaluate the effect of interpupillary distance (IPD) on stereoacuity using 2 kinds of stereoacuity tests in a normal population. The distance stereoacuities of 33 healthy volunteers with no evidence of ocular diseases were measured with the Frisby Davis distance (FD2) stereotest and a 3-dimensional monitor-based distance stereotest (distance 3-D stereotest). These 2 kinds of stereotests were repeated using horizontal periscopes to increase the IPD 2- and 3-fold in order to investigate the effect of IPD increase on stereoacuity. The mean age of the participants was 28.5 years (range 20–41 years). The mean logarithms of the individual minimum angle of stereodiscrimination (logMAS) were 1.04 ± 0.23 (range 0.70–1.48 logMAS) with the FD2 stereotest and 1.52 ± 0.19 (range 1.00–1.85 logMAS) with the distance 3-D stereotest. As the IPD increased 2- and 3-fold, the logMAS measured with the FD2 stereotest improved from 1.04 to 0.98 and 0.91 (P = 0.061 and P = 0.003), respectively, and those measured with the distance 3-D stereotest worsened from 1.52 to 1.73 and 1.85 (P < 0.001 and P < 0.001), respectively. Changes in IPD measured with the FD2 stereotest exhibited opposite effects to those measured with the distance 3-D stereotest. This reflects what is known to happen in the real world, i.e., that stereoacuity improves as IPD increases.Keywords
This publication has 14 references indexed in Scilit:
- Distance Stereotest Using a 3-Dimensional Monitor for Adult SubjectsAmerican Journal of Ophthalmology, 2011
- Development of distant stereoacuity in visually normal children as measured by the Frisby-Davis distance stereotestBritish Journal of Ophthalmology, 2008
- Stereoacuity is affected by induced phoria but returns toward baseline during vergence adaptationJournal of American Association for Pediatric Ophthalmology and Strabismus, 2007
- A New 3D Monitor–Based Random-Dot Stereotest for ChildrenInvestigative Ophthalmology & Visual Science, 2006
- Real Depth vs Randot StereotestsAmerican Journal of Ophthalmology, 2006
- Frisby Davis distance stereoacuity values in visually normal childrenBritish Journal of Ophthalmology, 2005
- Testing distance stereoacuity with the Frisby-Davis 2 (FD2) testAmerican Journal of Ophthalmology, 2005
- Statistical normal values of visual parameters that characterize binocular function in childrenOphthalmic and Physiological Optics, 2004
- Distance StereoacuityOphthalmology, 1993
- Stereopsis and contrastVision Research, 1989