High-Frequency Resonance Damping of DFIG-Based Wind Power System Under Weak Network
- 20 April 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 32 (3) , 1927-1940
Abstract
When operating in a micro or weak grid which has a relatively large network impedance, the doubly fed induction generator (DFIG)-based wind power generation system is prone to suffer high-frequency resonance due to the impedance interaction between the DFIG system and the parallel compensated network (series RL + shunt C). In order to improve the performance of the DFIG system as well as other units and loads connected to the weak grid, the high-frequency resonance needs to be effectively damped. In this paper, the proposed active damping control strategy is able to implement effective damping either in the rotor-side converter or in the grid-side converter, through the introduction of virtual positive capacitor or virtual negative inductor to reshape the DFIG system impedance and mitigate the high-frequency resonance. A detailed theoretical explanation on the virtual positive capacitor or virtual negative inductor has been given, and their parameters are also optimally designed. The proposed DFIG system damping control strategy has been validated by experimental results.Keywords
This publication has 26 references indexed in Scilit:
- Grid-Current-Feedback Active Damping for LCL Resonance in Grid-Connected Voltage-Source ConvertersIEEE Transactions on Power Electronics, 2015
- A Series- LC -Filtered Active Damper With Grid Disturbance Rejection for AC Power-Electronics-Based Power SystemsIEEE Transactions on Power Electronics, 2014
- Impedance Model-Based SSR Analysis for TCSC Compensated Type-3 Wind Energy Delivery SystemsIEEE Transactions on Sustainable Energy, 2014
- Virtual RC Damping of LCL-Filtered Voltage Source Converters With Extended Selective Harmonic CompensationIEEE Transactions on Power Electronics, 2014
- Real-time simulation of subsynchronous resonance in Type-III wind turbines2014
- Autonomous Control of Inverter-Interfaced Distributed Generation Units for Harmonic Current Filtering and Resonance Damping in an Islanded MicrogridIEEE Transactions on Industry Applications, 2013
- Impedance-Model-Based SSR Analysis for Type 3 Wind Generator and Series-Compensated NetworkIEEE Transactions on Energy Conversion, 2012
- Synthesis of Variable Harmonic Impedance in Inverter-Interfaced Distributed Generation Unit for Harmonic Damping Throughout a Distribution NetworkIEEE Transactions on Industry Applications, 2012
- Nyquist-Stability-Criterion-Based SSR Explanation for Type-3 Wind GeneratorsIEEE Transactions on Energy Conversion, 2012
- Mitigating SSR Using DFIG-Based Wind GenerationIEEE Transactions on Sustainable Energy, 2012