Increasing the Throughput of CE-SDS Experiments for the Determination of Purity in Biotherapeutic Products – A Bridging Case Study
Preprint
- 12 May 2025
- preprint
- Published by American Chemical Society (ACS) in ChemRxiv
Abstract
Capillary electrophoresis sodium dodecyl sulfate (CE-SDS) is a workhorse method for the characterization of purity and impurities attributes of biotherapeutic products. In this study, we compared the performance, throughput, and precision of two instruments manufactured by Sciex: the newly developed BioPhase 8800 and the classical PA800+. Four different monoclonal antibodies, anonymized as mAb A-D, were analyzed under reducing and non-reducing conditions and with manual and automated sample preparation on both instruments. In addition, a design of experiment (DoE) study was carried out to fully exploit the high throughput capabilities of the BioPhase 8800. Results demonstrate that data generated on the BioPhase 8800 were highly comparable to those obtained on the PA800+ instrument and that high precision was easily achievable with both manual and automated sample preparation. Moreover, because the throughput of the BioPhase 8800 is 8-fold higher than that of the PA800+, screening and DoE studies become a mainstream application of CE-SDS experiments.Keywords
All Related Versions
This publication has 20 references indexed in Scilit:
- From Efficiency to Yield: Exploring Recent Advances in CHO Cell Line Development for Monoclonal AntibodiesMolecular Biotechnology, 2024
- Efficient optimization of time‐varying inputs in a fed‐batch cell culture process using design of dynamic experimentsBiotechnology Progress, 2023
- Strategies to control therapeutic antibody glycosylation during bioprocessing: Synthesis and separationBiotechnology and Bioengineering, 2022
- Physicochemical factors of bioprocessing impact the stability of therapeutic proteinsBiotechnology Advances, 2022
- Optimization of muscle cell culture media using nonlinear design of experimentsBiotechnology Journal, 2021
- Interlaboratory method validation of capillary electrophoresis sodium dodecyl sulfate (CE‐SDS) methodology for analysis of mAbsElectrophoresis, 2021
- CE‐SDS method development, validation, and best practice—An overviewElectrophoresis, 2019
- Identification of process conditions influencing protein aggregation in Chinese hamster ovary cell cultureBiotechnology and Bioengineering, 2018
- Scale-Up of Protein Purification: Downstream Processing Issues2016
- Quality attributes of recombinant therapeutic proteins: An assessment of impact on safety and efficacy as part of a quality by design development approachBiotechnology Progress, 2012