Examination of Accuracy in the Assessment of Gastric Residual Volume
- 21 February 2014
- journal article
- research article
- Published by Wiley in Journal of Parenteral and Enteral Nutrition
- Vol. 39 (4) , 434-440
Abstract
Background. Increased gastric content from enteral nutrition intolerance is thought to place patients at risk for pulmonary aspiration. Although considered a questionable practice, blind gastric tube aspiration is the most common approach to measure gastric content. This simulated study evaluated the accuracy of residual volume (RV) assessment via tube aspirations made from known volumes by controlling the syringe pull technique, feeding tube properties, fluid viscosity, and placement of tubes in the fluid. Materials and Methods. This study was conducted in a metrology laboratory. Aspirates were obtained using a force measurement test system to control force of the syringe pull technique using 3 different procedures (slow 10 inches per minute [ipm], intermittent 10 ipm, and fast 40 ipm). Four different feeding tubes, 10 Fr and 18 Fr, each made of polyurethane and polyvinyl chloride, were placed in varying depths of 100 mL of either water or formula. The effect of fluid viscosity was also examined. Results. Overall, 108 RVs were analyzed using a force measurement test system. Actual content of RV was underestimated 19% on average and varied across tube size and viscosity. Intermittent and slow syringe pull techniques yielded greater aspirate quantities, although neither technique aspirated the full amount of volume available. The 10 Fr feeding tubes yielded larger RVs in more viscous fluid, yet the 18 Fr tubes performed better with fluids of lower viscosity. Conclusions. Based on this simulation, RV assessment does not accurately reflect the total volume of the contents available and, therefore, the clinical utility of this assessment should be further investigated.Keywords
This publication has 18 references indexed in Scilit:
- Guidelines for the Provision and Assessment of Nutrition Support Therapy in the Adult Critically Ill Patient:Journal of Parenteral and Enteral Nutrition, 2009
- Care and Patience Needed for Accurate Measure of Gastric Residual VolumesAmerican Journal of Critical Care, 2009
- Gastric Residual Volume (GRV) and Gastric Contents Measurement by RefractometryJournal of Parenteral and Enteral Nutrition, 2007
- Effect of Feeding‐Tube Properties on Residual Volume Measurements in Tube‐Fed PatientsJournal of Parenteral and Enteral Nutrition, 2005
- Clinical Use of Gastric Residual Volumes as a Monitor for Patients on Enteral Tube FeedingJournal of Parenteral and Enteral Nutrition, 2002
- Stopping Enteral Feeding for Arbitrary Gastric Residual Volume May Not Be Physiologically Sound: Results of a Computer Simulation ModelJournal of Parenteral and Enteral Nutrition, 1997
- Gastric fluid measurement by blind aspiration in paediatric patients: A gastroscopic evaluationCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1997
- Aspirating Gastric Residuals Causes Occlusion of Small‐Bore Feeding TubesJournal of Parenteral and Enteral Nutrition, 1993
- Measuring gastric contents during general anaesthesia: evaluation of blind gastric aspirationCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1989
- Determining gastric contents during general anaesthesia: evaluation of two methodsCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1987