Abstract
Background The quality and durability of fracture reduction play an important role in the functional prognosis of articulation. The purpose of this study was to investigate the radiological and clinical effects of compression bolts in the treatment of Schatzker I–IV tibial plateau fractures (TPFs). Methods Between May 2015 and April 2018, a total of 96 consecutive adult patients with operatively treated Schatzker I–IV TPFs were included and divided into two groups according to the internal fixations: Group 1 (unilateral locking plate) and Group 2 (unilateral locking plate combined with compression bolt). Data on demographic and fracture characteristics, postoperative follow-up imaging, intraoperative indicators, postoperative reduction quality and durability, clinical outcomes, and complications were retrospectively collected and compared between the two groups. Results There were no significant intergroup differences in preoperative baseline data, duration of operation, intra-operative blood loss, days in hospital, rate of immediate post-operative reduction loss, or complications. The time of fracture healing, the rate of secondary reduction loss, and the mean WOMAC score were significantly reduced compared with those in Group 1 (P = 0.024, 0.015, and 0.024, respectively). There were significant intergroup differences in the mean HSS score (89.0 ± 11.4 vs. 94.4 ± 6.7, P = 0.042), the mean Lysholm score (83.8 ± 9.6 vs. 88.4 ± 5.2, P = 0.027), and the mean SF-36 score (82.8 ± 12.5 vs. 90.5 ± 7.6, P = 0.001). Additionally, there were similar significant differences in subgroup analysis (only included patients with Schatzker II–III), except for WOMAC score. Conclusion Compared with unilateral locking plate fixation, unilateral locking plate combined with compressing bolt fixation can reduce the rate of secondary reduction loss, accelerate fracture healing, and show better clinical outcomes for patients with Schatzker I–IV TPFs.Keywords
Funding Information
- Non-profit Central Research Institute Fund of the Chinese Academy of Medical Sciences (2019PT320001)
- Natural Science Foundation of Hebei Province (CN) -Outstanding Youth Foundation (H2017206104)
- Innovation Project for Postgraduates of Hebei Province Education Department (CXZZBS2021069)
This publication has 26 references indexed in Scilit:
- How much articular displacement can be detected using fluoroscopy for tibial plateau fractures?Injury, 2015
- Dual locked plating of unstable bicondylar tibial plateau fracturesInjury, 2015
- Factors predicting the development of early osteoarthritis following lateral tibial plateau fractures: mid-term clinical and radiographic outcomes of 73 operatively treated patientsScandinavian Journal of Surgery, 2014
- Displaced Intra-Articular Calcaneal Fractures Treated in a Minimally Invasive FashionJournal of Bone and Joint Surgery, 2014
- Outcomes of Schatzker II Tibial Plateau Fracture Open Reduction Internal Fixation Using Structural Bone AllograftJournal of Orthopaedic Trauma, 2014
- Functional outcome of displaced intra-articular calcaneal fractures2012
- Three-Column Fixation for Complex Tibial Plateau FracturesJournal of Orthopaedic Trauma, 2010
- Schatzker Classification of Tibial Plateau Fractures: Use of CT and MR Imaging Improves AssessmentRadioGraphics, 2009
- Fracture and Dislocation Classification Compendium - 2007Journal of Orthopaedic Trauma, 2007
- Operative Treatment of 109 Tibial Plateau Fractures: Five- to 27-Year Follow-up ResultsJournal of Orthopaedic Trauma, 2007