A new leakage measurement method for damaged seal material
- 25 May 2018
- journal article
- research article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (7) , 075203
Abstract
In this paper, a new leakage measurement method based on the temperature field and temperature gradient field is proposed for detecting the leakage location and measuring the leakage rate in damaged seal material. First, a heat transfer leakage model is established, which can calculate the leakage rate based on the temperature gradient field near the damaged zone. Second, a finite element model of an infinite plate with a damaged zone is built to calculate the leakage rate, which fits the simulated leakage rate well. Finally, specimens in a tubular rubber seal with different damage shapes are used to conduct the leakage experiment, validating the correctness of this new measurement principle for the leakage rate and the leakage position. The results indicate the feasibility of the leakage measurement method for damaged seal material based on the temperature gradient field from infrared thermography.Keywords
Funding Information
- National Natural Science Foundation of China (Grant 11472152)
This publication has 24 references indexed in Scilit:
- Kinetic friction characterizations of the tubular rubber sealsTribology International, 2014
- Comparison of Long-Wave Infrared Imaging and Visible/Near-Infrared Imaging of Vegetation for Detecting Leaking ${\rm CO}_2$ GasIEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing, 2014
- Leakage quantification of compressed air using ultrasound and infrared thermographyMeasurement, 2012
- Remote sensing of gases by hyperspectral imaging: system performance and measurementsOptical Engineering, 2012
- Mechanics Analysis on Helium Leakage of Flexible CompositesMechanics of Advanced Materials and Structures, 2012
- Propane gas leak detection by infrared absorption using carbon infrared emitter and infrared cameraNDT & E International, 2011
- Automated Detection and Location of Leaks in Water Mains Using Infrared PhotographyJournal of Performance of Constructed Facilities, 2010
- Experimental Study on Damage-induced Helium Leakage in Flexible CompositesJournal of Reinforced Plastics and Composites, 2010
- Experimental study of helium leakage parameters in flexible compositeJournal of Applied Polymer Science, 2010
- Application of infrared thermography to the non-destructive testing of concrete and masonry bridgesNDT & E International, 2003