Contemporary outcomes of precision banding for high flow hemodialysis access
- 9 February 2022
- journal article
- research article
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 24 (6) , 1260-1267
Abstract
Objective: High-flow hemodialysis accesses are a well-recognized source of patient morbidity. Among available management strategies inflow constriction based on real-time physiologic flow monitoring offers a technically straightforward data-driven approach with potentially low morbidity. Despite the benefits offered by this approach, large contemporary series are lacking. Methods: A retrospective review of a prospectively maintained clinical database was undertaken to capture patients undergoing precision banding within a signal tertiary care institution between 2010 and 2019. Multivariable logistic regression modeling of thrombosis within 30 days and re-banding within 1 year were performed. Results: In total, 297 patients underwent banding during the study period for a total number of 398 encounters. Median [IQR] follow-up was 157 [52–373] days. Most accesses were upper arm with brachial artery inflow (84%) and half of the banding procedures were performed for flow imbalance based on exam, duplex, or fistulogram. Median flow rate reduction was 58%. The 30-day thrombosis rate after banding was 15 of 397 (3.8%) with a median time to event of 5.5 days (2–102). The re-banding rate within a year was 54 of 398 (14%) with a median time to re-banding of 134 days [56–224]. Multivariate logistic regression analysis using a univariate screen did not identify any predictors of 30-day thrombosis. Having a forearm radial-cephalic AVF compared to all other access types was protective against need for rebanding at 1 year (OR 0.12 95% CI 0.02–0.92, p = 0.04), as was flow imbalance as the indication for banding (OR 0.43 95% 0.23-0.79, p = 0.006). Conclusions: Precision banding offers an effective, low-morbidity approach for high-flow hemodialysis accesses. Early thrombosis is a rare event after precision banding, although in the long term, one in four patients will require re-banding to maintain control of flow volumes.Keywords
This publication has 19 references indexed in Scilit:
- High‐output heart failure secondary to arteriovenous fistulaHemodialysis International, 2011
- The MILLER banding procedure is an effective method for treating dialysis-associated steal syndromeKidney International, 2010
- ASDIN: Banding of Hemodialysis Access to Treat Hand Ischemia or Cardiac OverloadSeminars in Dialysis, 2009
- Experimental study of hemodynamics in procedures to treat access-related ischemiaJournal of Vascular Surgery, 2008
- The relationship between the flow of arteriovenous fistula and cardiac output in haemodialysis patientsNephrology Dialysis Transplantation, 2007
- Flow reduction in high-flow arteriovenous access using intraoperative flow monitoringJournal of Vascular Surgery, 2006
- Minimally Invasive Limited Ligation Endoluminal-assisted Revision (MILLER) for treatment of dialysis access-associated steal syndromeKidney International, 2006
- T-banding: A technique for flow reduction of a hyperfunctioning arteriovenous fistulaJournal of Vascular Surgery, 2006
- Fisteldrosselung - erfolgversprechendes Konzept bei peripherer MinderperfusionZentralblatt fur Chirurgie, 2002
- Heart Failure as a Complication of Hemodialysis Arteriovenous FistulaAnnals of Internal Medicine, 1972