Thermal analysis of magnetron injection gun for 170 GHz gyrotron
- 18 April 2020
- journal article
- research article
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 62 (8) , 2774-2781
Abstract
The 170 GHz gyrotron presented in this article has an operating voltage of 75 kV and a beam current up to 45 A, which requires the cathode emission temperature to reach above 1000°C. At such a high temperature, it is bound to cause the cathode of the electron gun to undergo thermal expansion and generate a certain amount of deformation, which may cause a large change in the performance parameters of the electron gun. This article uses thermal analysis simulation software ANSYS Workbench and COMSOL Multiphysics to perform thermal analysis processing on the electron gun. The thermal analysis results show that the temperature difference of the magnetron injection gun (MIG) cathode emission band is 4.6°C, and the total deformation is about 0.054 mm. The magnitude of the deformation is within an acceptable range and has little effect on the performance of the MIG. Comparing the thermal analysis results obtained by the two software, the simulation results agree well.Keywords
This publication has 13 references indexed in Scilit:
- A review on the sub-THz/THz gyrotronsInfrared Physics & Technology, 2016
- Magnetron Injection Gun for a Short Pulse, 0.67 THz Gyrotron for Remote Detection of Radioactive MaterialsIEEE Transactions on Terahertz Science and Technology, 2014
- Prospects for the study of biological systems with high power sources of terahertz radiationPhysical Biology, 2012
- Study and design of a single-anode magnetron injection gun for W band gyrotron2012
- Gyrotron and its Electron Beam Source: A ReviewJournal of Fusion Energy, 2011
- Thermal and Structural Analysis of Interaction Cavity and Its Effect on the Operating Mode Excitation for a 120 GHz, 1 MW GyrotronInternational Journal of Thermophysics, 2011
- Design of Magnetically Tunable Magnetron Injection Guns for Gyrotrons at Multiple FrequenciesIEEE Transactions on Plasma Science, 2011
- A Review on the Applications of High Power, High Frequency Microwave Source: GyrotronJournal of Fusion Energy, 2011
- Thermal and Structural Analysis of MIG for GyrotronJournal of Fusion Energy, 2010
- Theoretical and experimental investigation of a method for increasing the output power of a microwave tube based on the split-cavity oscillatorJournal of Applied Physics, 1994