Aortic Annulus Diameter Measurement: What Is the Best Modality?
Authors:
Open Access
- 1 January 2012
- journal article
- Published by Editorial Committee of Annals of Thoracic and Cardiovascular Surgery in Annals of Thoracic and Cardiovascular Surgery
- Vol. 18 (2) , 115-120
Abstract
Purpose: The purpose of this study was to clarify the most suitable method to measure the aortic annulus diameter. Patients and Methods: Fifty-five patients, who had undergone aortic valve replacement at Miyazaki University Hospital between April 2008 and May 2011, were included in this study. The maximum diameter of the sizing tool that could be inserted into the left ventricle through the annulus had been predicted, based on the diameter measured by each modality. Agreement with surgery and each imaging modality, namely transthoracic echocardiography, multidetector computed tomography and contrast angiography, were compared using Bland-Altman analysis. Results: The predicted aortic annulus diameter, based on the diameter measured by transthoracic echocardiography, multidetector computed tomography and contrast angiography, was 20.3 ± 2.50, 23.9 ± 3.19, and 23.5 ± 3.55 mm, respectively, whereas, the diameter measured at surgery was 23.7 ± 2.99 mm. Predicted aortic annulus diameter measured by multidetector computed tomography best agreed with that measured at surgery. Conclusion: We conclude that the aortic annulus diameter, measured by multidetector computed tomography, is the best modality to measure the aortic annulus diameter.Keywords
This publication has 18 references indexed in Scilit:
- Preoperative Assessment of Aortic Annulus Dimensions: Comparison of Noninvasive and Intraoperative MeasurementThe Annals of Thoracic Surgery, 2011
- A method for standardized computed tomography angiography-based measurement of aortic valvar structuresEuropean Heart Journal, 2010
- Use of Balloon Aortic Valvuloplasty to Size the Aortic Annulus Before Implantation of a Balloon-Expandable Transcatheter Heart ValveJACC: Cardiovascular Interventions, 2010
- Multimodal Assessment of the Aortic Annulus DiameterJACC, 2010
- Role of Multislice Computed Tomography in Transcatheter Aortic Valve ReplacementThe American Journal of Cardiology, 2009
- A Study of Functional Anatomy of Aortic-Mitral Valve Coupling Using 3D Matrix Transesophageal EchocardiographyCirculation: Cardiovascular Imaging, 2009
- Can Balloon Aortic Valvuloplasty Help Determine Appropriate Transcatheter Aortic Valve Size?JACC: Cardiovascular Interventions, 2008
- Electrocardiographically Gated Multi–Detector Row CT for Assessment of Valvular Morphology and Calcification in Aortic StenosisRadiology, 2002
- Comparing methods of measurement: why plotting difference against standard method is misleadingThe Lancet, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986