Influence of attachment bonding protocol on precision of the attachment in aligner treatments
Authors:
- 13 December 2019
- journal article
- research article
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 81 (1) , 30-40
Abstract
Aim Precise bonding of attachments in aligner treatment is crucial to achieve the intended tooth movement. Thus, we evaluated five different bonding protocols for attachments used in aligner treatments with the goal of identifying the most precise protocol. Methods One ellipsoid and one rectangular attachment were exemplarily chosen and examined. All attachments were bonded using the same template aligner, which was produced by thermoforming. The bonding process was repeated 30 times with each protocol for statistical analysis. The protocols differed in the type of composite used (high viscous, low viscous), the additional application of a perforation in the attachment reservoir, and the use of a two-phase procedure with high viscous composite. All bonded attachments were laser scanned and compared to the attachments of a master model using a surface/surface matching algorithm to determine the precision, i.e., highest aberrations (maximum vertical distance) between the attachment of the master and results obtained from the various bonding protocols. Furthermore, the excessive amounts of composite bonded around the attachments were measured and compared. Results The two-phase procedure had a median aberration of 0.13 mm and a median amount of excessive composite of 7.40 mm2 (ellipsoid attachment). With the low viscous composite without a perforation in the template reservoir, similar results were achieved (median 0.13 mm) regarding the maximum vertical distance, but had an excess area of 33.50 mm2. Conclusion In this in vitro study, the bonding protocol influenced the precision of bonded attachments. The bonding protocol with high viscous composite without a perforation in the attachment reservoir was the most inaccurate. The use of a low viscous composite or attachments made by a two-phase procedure with high viscous composite revealed more precise results.Keywords
This publication has 24 references indexed in Scilit:
- Periodontal health in teenagers treated with removable aligners and fixed orthodontic appliancesJournal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2015
- Initial force systems during bodily tooth movement with plastic aligners and composite attachments: A three-dimensional finite element analysisThe Angle Orthodontist, 2015
- Flowable Resin Composites: A Systematic Review and Clinical ConsiderationsJournal of Clinical and Diagnostic Research, 2015
- Treatment outcome and efficacy of an aligner technique – regarding incisor torque, premolar derotation and molar distalizationBMC Oral Health, 2014
- Forces and moments generated by removable thermoplastic aligners: Incisor torque, premolar derotation, and molar distalizationAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2014
- Characterization of nanofilled compared to universal and microfilled compositesDental Materials, 2007
- Applications of Surface–Surface Matching Algorithms for Determination of Orthodontic Tooth MovementsComputer Methods in Biomechanics and Biomedical Engineering, 2003
- The minimal width of the periodontal spaceJournal of Oral Rehabilitation, 1984
- The philosophy of the tooth positioning applianceAmerican Journal of Orthodontics and Oral Surgery, 1945
- Tissue changes incidental to orthodontic tooth movementInternational Journal of Orthodontia, Oral Surgery and Radiography, 1932