Successful management of a broken epidural catheter!!!
Open Access
- 1 January 2017
- journal article
- case report
- Published by Medknow in Saudi Journal of Anaesthesia
- Vol. 11 (2) , 228-231
Abstract
Breakage of epidural catheter though rare is a well-known but worrisome complication. Visualization of retained catheter is difficult even with modern radiological imaging techniques, and active surgical intervention might be necessary for removal of catheter fragment. We report such a case of breakage of an epidural catheter during its removal which led to surgical intervention.Keywords
This publication has 5 references indexed in Scilit:
- Breakage of a thoracic epidural catheter during its removal -A case report-Korean Journal of Anesthesiology, 2010
- Quebra de cateteres peridurais: etiologia, prevenção e condutaRevista Brasileira de Anestesiologia, 2008
- Management of the sheared epidural catheter: is surgical extraction really necessary?Journal of Clinical Anesthesia, 2007
- Knotting of an epidural catheter: a rare complication.2007
- Epidural catheter breakage: a possible mechanismInternational Journal of Obstetric Anesthesia, 2000