A New On-Orbit Geometric Self-Calibration Approach for the High-Resolution Geostationary Optical Satellite GaoFen4
- 29 March 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 11 (5) , 1670-1683
Abstract
With the successful launch of GaoFen4 (GF4), on-orbit high accuracy geometric calibration for the high-resolution geostationary optical satellite will be a new research topic. With the improvement in the geometric resolution from geostationary orbit, it will become more and more difficult to meet the requirements of both high geometric resolution and large coverage for the available reference data. The purpose of this paper is to explore a new self-calibration mode for GF4 and future high-resolution geostationary optical area array cameras based on the fewest ground control points (GCPs). To overcome the problems of overparameterization, strong correlation and lower significance of the traditional rigorous imaging model, the simplified physical internal model is proposed, and its effectiveness in describing and compensating for the camera internal distortion is verified. Based on the simplified physical internal model, the self-calibration method based on two GCPs and evenly distributed tie points of two images is proposed for the high accuracy estimation of the calibration parameters. The GCPs can be used to provide the absolute geographical constraints for scale information, and the tie points can be used to provide the global constraints for optimum estimation. After calibration, the internal distortion is well compensated, and the positioning accuracy with relatively few GCPs is shown to be better than 1.0 pixels for both the panchromatic and near-infrared sensor and the intermediate infrared sensor. This paper will provide a new usable concept and approach for the future higher resolution geostationary area array optical camera to overcome the stringent requirements of both high resolution and a large area of reference data for the traditional calibration method.Keywords
Funding Information
- National Natural Science Foundation of China (91438203, 91438111)
- National Basic Research Program of China (2014CB744201)
- Program for New Century Excellent Talents in University
This publication has 29 references indexed in Scilit:
- Geometric Analysis and Self‐Calibration of ADS40 ImageryThe Photogrammetric Record, 2013
- Optical System Error Analysis and Calibration Method of High-Accuracy Star TrackersSensors, 2013
- ATTITUDE ASSESSMENT USING PLEIADES-HR CAPABILITIESThe International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences, 2012
- PLEIADES HR IN FLIGHT GEOMETRICAL CALIBRATION : LOCATION AND MAPPING OF THE FOCAL PLANEThe International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences, 2012
- Review of developments in geometric modelling for high resolution satellite pushbroom sensorsThe Photogrammetric Record, 2012
- Orientation and self‐calibration of ALOS PRISM imageryThe Photogrammetric Record, 2008
- In‐flight geometric calibration of different cameras of IRS‐P6 using a physical sensor modelThe Photogrammetric Record, 2008
- Camera self-calibration from unknown planar structures enforcing the multiview constraints between collineationsIEEE Transactions on Pattern Analysis and Machine Intelligence, 2002
- Bundle Adjustment with Self–Calibration Using Straight LinesThe Photogrammetric Record, 2002
- Digital camera self-calibrationISPRS Journal of Photogrammetry and Remote Sensing, 1997