Closed-Perfusion Transretinal ERG Setup for Preclinical Drug and Nanostructure Testing
Open Access
- 7 November 2024
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (4) , 1256-1265
Abstract
Objective: The isolated mammalian retina may serve as a sensitive biosensor for preclinical drug testing, including eye drugs and a broader range of pharmaceuticals. To facilitate testing with minimal amounts of drug molecules or nanostructures, we developed a closed-perfusion transretinal electroretinography (tERG) setup. Methods: The major challenge with small amounts of circulating perfusate was maintaining retinal viability and stability during long experiments. We conducted ex vivo tERG using WT C57BL/6J and Gnat1 -/- mice to assess rod- and cone-mediated light signals. The dark-adapted retina was stimulated with full-field light flashes while perfused at 5-6 ml/min. Results: The minimum perfusate needed in our closed-circulation was around 50 ml. Penicillin-Streptomycin (Pen-Strep) was indispensable for long recordings. Rod responses remained stable for at least 42 hours, the longest recording we conducted, with the retina still responsive, and rod and cone bipolar cell responses for up to 12 hours. IBMX (3-isobutyl-1-methylxanthine), a non-specific phosphodiesterase (PDE) inhibitor with reversible effects, validated our setup. We used our setup to test the zwitterionic polymer poly(sulfobetaine methacrylate) (PSMBA), serving as a promising material for thermoresponsive nanostructures, and the corresponding monomer SBMA for possible harmful effects on mouse rod and bipolar cell functioning. Conclusion: Our closed-perfusion tERG setup enables long experiments with small amounts of perfusate. PSMBA or SBMA had no effect on rod and bipolar cell responses. Significance: This method is applicable for assessing drug functionality, as well as conducting preliminary biocompatibility and toxicity testing using small amounts of molecules or nanostructures that could impact neuronal or synaptic function.Keywords
This publication has 45 references indexed in Scilit:
- Drug delivery to retinal photoreceptorsDrug Discovery Today, 2019
- Recognition Receptors in Biosensors2010
- ATP Consumption by Mammalian Rod Photoreceptors in Darkness and in LightCurrent Biology, 2008
- Testing retinal toxicity of drugs in animal models using electrophysiological and morphological techniquesDocumenta Ophthalmologica, 2008
- Retinal electrophysiology for toxicology studies: Applications and limits of ERG in animals and ex vivo recordingsExperimental and Toxicologic Pathology, 2008
- The Origin of the Major Rod- and Cone-Driven Components of the Rodent Electroretinogram and the Effect of Age and Light-Rearing History on the Magnitude of These Components1998
- Effects of IBMX on the ERG of the isolated perfused cat eyeVision Research, 1987
- Studies on the mass receptor potential of the isolated frog retinaVision Research, 1969
- Development of the ERG in Relation to Histological Differentiation of the Retina in Man and AnimalsArchives of Ophthalmology (1950), 1960
- Sauerstoff berdruck und b-Welle des Elektroretinogramms vom isolierten FroschaugePflügers Archiv - European Journal of Physiology, 1958