A preliminary study on post-occupancy evaluation of four office buildings in the UK based on the Analytic Hierarchy Process
- 17 July 2018
- journal article
- research article
- Published by Taylor & Francis in Intelligent Buildings International
- Vol. 10 (4) , 234-246
Abstract
There is a lack of a systematic decision-making criterion to select appropriate indicators for Post-Occupancy Evaluation (POE) analysis due to the fact that significant levels of various POE determinants are indeterminate. The present work aims to identify the degree of importance of a set of POE determinants based on Analytic Hierarchy Process (AHP). A case study of POE for four office buildings in the UK has been conducted using the AHP to ascertain the significance levels of three main factors identified, namely, Indoor Environment Quality (IEQ), Occupants’ Performance (OP) and Workplace Quality (WQ) as well as three groups of sub-factors affiliated to the main factors based on questionnaire surveys of the building occupants. The results show that the priority factors of the three main evaluation metrics, IEQ, OP, WQ are 0.595, 0.183 and 0.222, respectively, indicating that of these three factors the IEQ is the paramount factor in relation to the POE level of the office buildings. Moreover, the global priorities of all sub-factors linked to the main factors are obtained, providing a strategy reference of choosing indicators as per the priorities for a continuing POE in the further survey and measurement.Keywords
Funding Information
- UK Engineering and Physical Sciences Research Council (EPSRC) Engineering Doctor Training Grant (EP/G037787/1)
This publication has 31 references indexed in Scilit:
- Occupant productivity and office indoor environment quality: A review of the literatureBuilding and Environment, 2016
- Self-reported health and comfort in ‘modern’ office buildings: first results from the European OFFICAIR studyIndoor Air, 2015
- BOSSA: a multidimensional post-occupancy evaluation toolBuilding Research & Information, 2015
- Post-occupancy studies of an office environment: Energy performance and occupants' satisfactionBuilding and Environment, 2013
- Post-occupancy evaluation of 20 office buildings as basis for future IEQ standards and guidelinesEnergy and Buildings, 2012
- Key performance indicators (KPIs) and priority setting in using the multi-attribute approach for assessing sustainable intelligent buildingsBuilding and Environment, 2010
- Post-Occupancy Evaluation of a Transformed Nursing Home: The First Four Green House® SettingsJournal of Housing For the Elderly, 2009
- CONSISTENCY IN THE ANALYTIC HIERARCHY PROCESS: A NEW APPROACHInternational Journal of Uncertainty, Fuzziness and Knowledge-Based Systems, 2006
- Learning more from our buildings - or just forgetting less?Building Research & Information, 2003
- Post-occupancy evaluation - where are you?Building Research & Information, 2001