Mechanical failure of a Thompson’s hemiarthoplasty stem 28 years post-implantation: an investigation with electron microscopy
Authors:
- 1 February 2007
- journal article
- case report
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 18 (6) , 1135-1139
Abstract
Τhe authors would like to report a mechanical failure of a Thompson’s prosthesis, 28 years post-implantation. A detailed examination of the specimen revealed no defects in the prosthesis and a dominating ‘brittle component’ fracture of the stem. In this context the detailed fractographic study by scanning electron microscopy (SEM) revealed no detrimental manufactural defects that may have produced microcracks and consequently risked initiating the fracture propagation. In contrast, the fracture was mainly a fatigue one with a mixed mode of microscopic trans- and intergranular crack propagation. To the best of our knowledge, such a mechanism of implant failure in a cementless stem has never before reached 28 years neither in a Thompson’s nor any other type of prosthesis, and in the already reported case, it exceeded 30 years [N. Wolson and J. P. Waadell, Can. J. Surg. 38(6) (1995) 542], however the stem’s ultrastructure has never been investigated under electron microscopy, which arguably can provide a useful assessment of a fatigue fracture. Τhe authors introduce the question of revising our standards when evaluating the newly designed and expensive implants and propose re-focusing on surgical technique, rather than purely on implant properties.Keywords
This publication has 8 references indexed in Scilit:
- Moore hemiarthroplasty functioning for 33 years: a case report.1995
- Fractography of Modern Engineering Materials: Composites and Metals1987
- Stem fractures of extra-heavy Cobra femoral hip prostheses. Report of two cases.1984
- Stem Fractures of Extra-heavy Cobra Femoral Hip ProsthesesClinical Orthopaedics and Related Research, 1984
- A retrospective study of Moore and Thompson hemiarthroplasty. A review of 599 surgical cases and an analysis of the technical complications.1982
- Fractured Stem in Total Hip Replacement:A Clinical Review of 120 CasesActa Orthopaedica, 1982
- Fractography and Materials Science1981
- "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.1979