Is smaller high enough? Another piece in the puzzle of stress, strain, size, and systems
Open Access
- 1 January 2009
- journal article
- editorial
- Published by Springer Nature in Critical Care
- Vol. 13 (2) , 126-2
Abstract
Extracorporeal lung-supporting procedures open the possibility of staying within widely accepted margins of 'protective' mechanical ventilation (tidal volume of less than 6 mL per kg of predicted ideal body weight and plateau pressure of less than 30 cm H2O) in most any case of respiratory failure or even of further reducing ventilator settings while still providing adequate gas exchange. There is evidence that, at least in some patients, a further reduction in tidal volumes might be beneficial. Extracorporeal procedures to support the lungs have undergone tremendous technical developments, thus reducing the procedure-related risks. However, what is true for ventilator settings should also be true for extracorporeal procedures: studies will have to demonstrate a convincing risk-benefit ratio. In addition, a simple reduction of the tidal volume will certainly not be the right answer. If extracorporeal support largely influences gas exchange, the 'optimal' tidal volume/positive end-expiratory pressure ratio keeping stress and strain low and avoiding alveolar derecruitment will still have to be individually defined.Keywords
This publication has 9 references indexed in Scilit:
- Pumpless extracorporeal interventional lung assist in patients with acute respiratory distress syndrome: a prospective pilot studyCritical Care, 2009
- ARDSnet Ventilatory Protocol and Alveolar HyperinflationAmerican Journal of Respiratory and Critical Care Medicine, 2007
- Pumpless extracorporeal lung assist for protective mechanical ventilation in experimental lung injury*Critical Care Medicine, 2007
- Tidal Hyperinflation during Low Tidal Volume Ventilation in Acute Respiratory Distress SyndromeAmerican Journal of Respiratory and Critical Care Medicine, 2007
- A new pumpless extracorporeal interventional lung assist in critical hypoxemia/hypercapnia*Critical Care Medicine, 2006
- Pumpenfreie extrakorporale Lungenunterst tzung mit arterioven sem Shunt beim schweren akuten Lungenversagen des ErwachsenenDer Anaesthesist, 2004
- Higher versus Lower Positive End-Expiratory Pressures in Patients with the Acute Respiratory Distress SyndromeThe New England journal of medicine, 2004
- Influence of Tidal Volume on Alveolar RecruitmentAmerican Journal of Respiratory and Critical Care Medicine, 2001
- Ventilation with Lower Tidal Volumes as Compared with Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress SyndromeThe New England journal of medicine, 2000