Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure
- 1 August 2008
- journal article
- research article
- Published by Springer Nature in European Spine Journal
- Vol. 17 (8) , 1049-1056
Abstract
Interspinous implants are used to treat lumbar spinal stenosis or facet joint arthritis. The aims of implanting interspinous devices are to unload the facet joints, restore foraminal height and provide stability especially in extension but still allow motion. The aim of this in vitro study was to compare four different interspinous implants––Colfex, Wallis, Diam and X-Stop––in terms of their three-dimensional flexibility and the intradiscal pressure. Twenty-four human lumbar spine specimens were divided into four equal groups and tested with pure moments in flexion/extension, lateral bending and axial rotation: (1) intact, (2) defect, (3) after implantation. Range of motion and the intradiscal pressure were determined.In each implant-group the defect caused an increase in range of motion by about 8% in lateral bending to 18% in axial rotation. Implantation had similar effects with all four implants. In extension, Coflex, Wallis, Diam, and X-Stop all overcompensated the instability caused by the defect and allowed about 50% of the range of motion of the intact state. In contrast, in flexion, lateral bending and axial rotation the values of the range of motion stayed about the values of the defect state. Similarly the intradiscal pressure after implantation was similar to that of the intact specimens in flexion, lateral bending and axial rotation but much smaller during extension. All tested interspinous implants had a similar effect on the flexibility: they strongly stabilized and reduced the intradiscal pressure in extension, but had almost no effect in flexion, lateral bending and axial rotation.Keywords
This publication has 18 references indexed in Scilit:
- Are the spines of calf, pig and sheep suitable models for pre-clinical implant tests?European Spine Journal, 2007
- Validity and interobserver agreement of a new radiographic grading system for intervertebral disc degeneration: Part I. Lumbar spineEuropean Spine Journal, 2005
- The Effects of an Interspinous Implant on the Kinematics of the Instrumented and Adjacent Levels in the Lumbar SpineSpine, 2003
- Dynamic Stabilization of the Lumbar Spine and Its Effects on Adjacent SegmentsJournal of Spinal Disorders & Techniques, 2003
- The Effects of an Interspinous Implant on Intervertebral Disc PressuresSpine, 2003
- The Relationship Between Disc Degeneration, Facet Joint Osteoarthritis, and Stability of the Degenerative Lumbar SpineJournal of Spinal Disorders, 2000
- Lumbar Spinal Stenosis: Conservative or Surgical Management?Spine, 2000
- Nonoperative Treatment for Lumbar Spinal StenosisSpine, 2000
- Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implantsEuropean Spine Journal, 1998
- Preliminary Design and Experimental Studies of a Novel Soft Implant for Correcting Sagittal Plane Instability in the Lumbar SpineSpine, 1997