Transient-Based Fault Location on Three-Terminal and Tapped Transmission Lines Not Requiring Line Parameters
Authors:
- Masoud DavoudiMDMasoud Davoudi
- Javad SadehJSJavad Sadeh
- Ebadollah KamyabEKEbadollah Kamyab
- 19 April 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (1) , 179-188
Abstract
In this paper, fault location on three-terminal and tapped transmission lines without requiring line parameters is presented, which mitigates the effect of line parameters variations due to weather and loading conditions on fault location accuracy. For three-terminal lines, a fault location method is presented which utilizes post-fault measurements of all three terminals. For tapped lines, two methods are presented. The first one uses post-fault measurements of the main two terminals. The second one needs one cycle of pre-fault measurements at main terminals as well. Synchronized transient-based measurements are used in methods proposed in this paper. In all presented methods, the fault location problem is converted to an optimization problem and then solved to find the line parameters and the accurate location of fault. The simulations are carried out by ATP/EMTP software and the presented algorithms are executed by MATLAB. Simulation results assess the effects of fault resistance, type and inception angle on the accuracy of presented methods. Further discussion is also provided on the impacts of synchronization errors, noisy measurements, and nonresistive faults.Keywords
This publication has 21 references indexed in Scilit:
- Traveling-Wave-Based Fault-Location Algorithm for Hybrid Multiterminal CircuitsIEEE Transactions on Power Delivery, 2016
- Unsynchronised fault‐location technique for three‐terminal linesIET Generation, Transmission & Distribution, 2015
- Parameter‐free fault location for transmission lines based on optimisationIET Generation, Transmission & Distribution, 2015
- Transmission-Line Fault Analysis Using Synchronized SamplingIEEE Transactions on Power Delivery, 2014
- Accurate Single-Phase Fault-Location Method for Transmission Lines Based on K-Nearest Neighbor Algorithm Using One-End VoltageIEEE Transactions on Power Delivery, 2012
- Combined solution for fault location in three-terminal lines based on wavelet transformsIET Generation, Transmission & Distribution, 2010
- A Fault-Location Method for Application With Current Differential Relays of Three-Terminal LinesIEEE Transactions on Power Delivery, 2007
- Optimal Estimate of Transmission Line Fault Location Considering Measurement ErrorsIEEE Transactions on Power Delivery, 2007
- Travelling Wave Based Fault Location for Teed CircuitsIEEE Transactions on Power Delivery, 2005
- Fault Location on a Transmission Line Using Synchronized Voltage MeasurementsIEEE Transactions on Power Delivery, 2004