Prediction of Insulation Sensitive Parameters of Power Transformer Using Detrended Fluctuation Analysis Based Method
- 4 August 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 1963-1973
Abstract
Utilities prefer to perform a condition-based assessment of power transformer insulation in the least possible shutdown time. It is essential to estimate the values of various insulation condition sensitive performance parameters with higher accuracy. In the present work, a technique for the estimation of performance parameters, moisture content of paper, dissipation factor of the entire oil-paper insulation, paper conductivity, and activation energy is proposed. The evaluation of these parameters using reported techniques requires complete measurement of polarization and depolarization current profile, which requires around 20000 s of measurement time. The present method uses a forecasted polarization current profile obtained from 600 s of measured polarization current data. Detrended Fluctuation Analysis is applied to the forecasted polarization current data obtained from various in-service power transformers to obtain a suitable parameter. It is shown that this parameter maintains well-defined relationships with parameters; moisture content of paper, dissipation factor of oil-paper insulation, paper conductivity, and activation energy. The proposed technique is beneficial for utilities as it eliminates the requirement of measuring depolarization current and return voltage measurement for estimating activation energy.Keywords
Funding Information
- DST, SERB, Govt. of India (CRG/2018/001374)
This publication has 29 references indexed in Scilit:
- Condition assessment of cellulosic part in power transformer insulation using transfer function zero of modified debye modelIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- On the Feasibility of Using Poles Computed from Frequency Domain Spectroscopy to Assess Oil Impregnated Paper Insulation ConditionsEnergies, 2013
- Understanding the impacts of moisture and thermal ageing on transformer's insulation by dielectric response and molecular weight measurementsIEEE Transactions on Dielectrics and Electrical Insulation, 2008
- Dielectric response of mineral oil impregnated cellulose and the impact of agingIEEE Transactions on Dielectrics and Electrical Insulation, 2007
- Effects of the Insulation Quality on the Frequency Response of Power TransformersJournal of Electrical Engineering & Technology, 2006
- Deriving an Equivalent Circuit of Transformers Insulation for Understanding the Dielectric Response MeasurementsIEEE Transactions on Power Delivery, 2005
- Applications of dielectric spectroscopy in time and frequency domain for HV power equipmentIEEE Electrical Insulation Magazine, 2003
- Review of modern diagnostic techniques for assessing insulation condition in aged transformersIEEE Transactions on Dielectrics and Electrical Insulation, 2003
- Determination of moisture content in mass impregnated cable insulation using low frequency dielectric spectroscopy2002
- Review of chemical indicators of degradation of cellulosic electrical paper insulation in oil-filled transformersIEE Proceedings - Science, Measurement and Technology, 1994