Longitudinal assessment of tissue properties and cardiac diffusion metrics of the ex vivo porcine heart at 7 T: Impact of continuous tissue fixation using formalin
Open Access
- 24 March 2020
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (7) , e4298
Abstract
In this study we aimed to assess the effects of continuous formalin fixation on diffusion and relaxation metrics of the ex vivo porcine heart at 7 T. Magnetic resonance imaging was performed on eight piglet hearts using a 7 T whole body system. Hearts were measured fresh within 3 hours of cardiac arrest followed by immersion in 10% neutral buffered formalin. T2* and T2 were assessed using a gradient multi‐echo and multi‐echo spin echo sequence, respectively. A spin echo and a custom stimulated echo sequence were employed to assess diffusion time‐dependent changes in metrics of cardiac diffusion tensor imaging. SNR was determined for b = 0 images. Scans were performed for 5 mm thick apical, midcavity and basal slices (in‐plane resolution: 1 mm) and repeated 7, 15, 50, 100 and 200 days postfixation. Eigenvalues of the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) decreased significantly (P < 0.05) following fixation. Relative to fresh hearts, FA values 7 and 200 days postfixation were 90% and 80%, while respective relative ADC values at those fixation stages were 78% and 92%. Statistical helix and sheetlet angle distributions as well as respective mean and median values showed no systematic influence of continuous formalin fixation. Similar to changes in the ADC, values for T2, T2* and SNR dropped initially postfixation. Respective relative values compared with fresh hearts at day 7 were 64%, 79% and 68%, whereas continuous fixation restored T2, T2* and SNR leading to relative values of 74%, 100%, and 81% at day 200, respectively. Relaxation parameters and diffusion metrics are significantly altered by continuous formalin fixation. The preservation of microstructure metrics following prolonged fixation is a key finding that may enable future studies of ventricular remodeling in cardiac pathologies.Keywords
Funding Information
- Bundesministerium für Forschung, Technologie und Raumfahrt (01EO1504)
This publication has 43 references indexed in Scilit:
- Diffusion Spectrum MRI Tractography Reveals the Presence of a Complex Network of Residual Myofibers in Infarcted MyocardiumCirculation: Cardiovascular Imaging, 2009
- Aldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissueMagnetic Resonance in Medicine, 2009
- Postmortem MRI of human brain hemispheres: T2 relaxation times during formaldehyde fixationMagnetic Resonance in Medicine, 2009
- Postmortem interval alters the water relaxation and diffusion properties of rat nervous tissue — Implications for MRI studies of human autopsy samplesNeuroImage, 2009
- Diffusion tensor imaging at low SNR: nonmonotonic behaviors of tensor contrastsMagnetic Resonance Imaging, 2008
- Statistical Analysis of the Angle of Intrusion of Porcine Ventricular Myocytes from Epicardium to Endocardium Using Diffusion Tensor Magnetic Resonance ImagingThe Anatomical Record, 2007
- MR diffusion tensor imaging study of postinfarct myocardium structural remodeling in a porcine modelMagnetic Resonance in Medicine, 2007
- Magnetic Resonance Imaging of MyelinNeurotherapeutics, 2007
- Dependence on diffusion time of apparent diffusion tensor of ex vivo calf tongue and heartMagnetic Resonance in Medicine, 2005
- Magnetic resonance imaging and mathematical modeling of progressive formalin fixation of the human brainMagnetic Resonance in Medicine, 2005