Influence of decreased sample size on cone calorimeter results
Authors:
- 15 March 2011
- journal article
- research article
- Published by Wiley in Fire and Materials
- Vol. 36 (1) , 63-73
Abstract
SUMMARY: Cone calorimeter sample size sensitivity and the influence of sample size on the results were studied in order to investigate the possibility to use smaller samples than prescribed by the standard. The influence of the position of the sample on the sample holder of the decreased samples was also studied. Samples of birch plywood, industrial two‐component polyurethane adhesive and polypropylene wax were tested. The results from standard size sample experiments, 100 cm 2, and decreased sample size, 50 and 25 cm2, were compared, in order to investigate the sample size influence on the results. The experiments were performed using an external heat flux of 50kW/ m2. The results show differences between the sample types. The measured heat release rates for plywood and polyurethane adhesive indicate that the sample size is possible to down‐scale, while the polypropylene wax results show the opposite. All sample types and sizes show constant results for the effective heat of combustion, indicating down‐scalability. For in‐house testing and screening of materials, downscaling can be used for most sample types. However, results from experiments carried out with decreased sample size should not be compared to results from experiments executed according to the standard procedure. Copyright © 2011 John Wiley & Sons, Ltd.Keywords
This publication has 24 references indexed in Scilit:
- Development of fire‐retarded materials—Interpretation of cone calorimeter dataFire and Materials, 2007
- Estimation of heat release rate for polymer–filler composites by cone calorimetryPolymer Testing, 2004
- Modelling the combustion of solid-phase fuels in cone calorimeter experimentsFire and Materials, 1999
- Application of cone calorimeter for the assessment of class of flame retardants for polypropyleneFire and Materials, 1998
- The effects of specimen edge conditions on heat release rateFire and Materials, 1993
- Heat release rate: The single most important variable in fire hazardFire Safety Journal, 1992
- Piloted ignition of wood: A reviewFire and Materials, 1991
- Rate of heat release measurement using the Cone CalorimeterJournal of Thermal Analysis and Calorimetry, 1989
- Larger specimens for determining rate of heat release in the cone calorimeterFire and Materials, 1986
- Estimation of rate of heat release by means of oxygen consumption measurementsFire and Materials, 1980