In Vitro Evaluation of a Non-Invasive Photoplethysmography Based Intracranial Pressure Sensor
Open Access
- 30 December 2022
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 13 (1) , 534
Abstract
Intracranial pressure (ICP) is an important measurement in the treatment of Traumatic Brain Injury (TBI). Currently, ICP can only be measured invasively, which exposes patients to operative risk and can only be performed by neurosurgeons. Hence, there is a significant need for a non-invasive ICP technology. This paper describes the evaluation of a novel non-invasive intracranial pressure (nICP) monitor which uses the Photoplethysmogram (PPG) to measure the ICP. The monitor was evaluated in an in vitro model that simulated cerebral haemodynamics and allowed the controlled manipulation of ICP. A number of features from the PPG were extracted and utilised in a machine learning model to estimate ICP. Three separate measurements in which the ICP was varied were performed, and the estimated ICP (nICP) was compared with reference (invasive) ICP measurements. The ICP estimated by the nICP monitor was highly correlated with reference ICP measurements (Pearson’s correlation coefficient between 0.95 and 0.98). The nICP monitor also showed a low Root Mean Square Error from the reference ICP measure (3.12, 1.48, and 1.45 mmHg). Analysis of agreement by Bland and Altman also revealed good agreement between the two techniques. The optical nICP monitor was able to estimate the ICP non-invasively from an in vitro model simulating intracranial hypertension. The non-invasive ICP monitor showed very promising results which can set the base for further investigations. This work contributes significantly to the quest for non-invasive ICP monitoring in Traumatic Brain Injury (TBI), and paves the way for further research in this field.Keywords
Funding Information
- National Institute for Health and Care Research (II-LA-0216-20005)
This publication has 33 references indexed in Scilit:
- Age-Related Changes in Spontaneous Oscillations Assessed by Wavelet Transform of Cerebral Oxygenation and Arterial Blood Pressure SignalsJournal of Cerebral Blood Flow & Metabolism, 2013
- Intraparenchymal vs Extracranial Ventricular Drain Intracranial Pressure Monitors in Traumatic Brain Injury: Less Is More?Journal of the American College of Surgeons, 2012
- Phantom with Pulsatile Arteries to Investigate the Influence of Blood Vessel Depth on Pulse Oximeter Signal StrengthSensors, 2012
- Near Infrared Brain and Muscle Oximetry: From the Discovery to Current ApplicationsJournal of Near Infrared Spectroscopy, 2012
- Optimizing probe design for an implantable perfusion and oxygenation sensorBiomedical Optics Express, 2011
- Optofluidic phantom mimicking optical properties of porcine liversBiomedical Optics Express, 2011
- Monitoring Intracranial Pressure in Traumatic Brain InjuryAnesthesia & Analgesia, 2008
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetryJournal of Biomedical Optics, 2006
- Monitoring and interpretation of intracranial pressureJournal of Neurology, Neurosurgery & Psychiatry, 2004