Effect of saliva on accuracy of digital dental implant transfer using two different materials of intraoral scan bodies with different exposed lengths
Open Access
- 23 November 2024
- journal article
- research article
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-10
Abstract
Background: The accuracy of digital implant transfer is currently under investigation in relation to the effect of saliva, scan body material, and exposed length. Methods: Six completely edentulous casts with four implant fixtures were fabricated. The four implant fixtures in each cast were placed below the crest of the ridge of the casts by 1.5 mm. The four implant fixtures were alternately attached to four implant scan bodies (PEEK) Group (I) and (TITANIUM) Group (II). For each cast, two flexible polyurethane layers with varying thicknesses were fabricated and molded on the six 3D printed identical casts after the placement of the implant fixtures in each cast for the soft tissue moulage in the cast. The six casts were alternately covered with a 2 mm and 4 mm thick layer. The six reference casts were recorded using a coordinate measurement machine (CMM) and subsequently scanned with an Intraoral scanner (MEDIT I 700). The scanning was conducted under both dry and wet conditions, with artificial saliva applied. The scanning platform consisted of two transparent acrylic boxes, and the process followed standardized scanning conditions using a digital lux meter (n = 48). The mean difference and standard deviation values (± SD) between the implant scan bodies measured on the reference and experimental scans were calculated using the inspection software program (Medit design). Data were fed to the computer and analyzed using IBM SPSS software package version 20.0. (Armonk, NY: IBM Corp). The Kolmogorov-Smirnov test and Shapiro-Wilk test were used to verify the normality of distribution. Quantitative data mean and standard deviation. The significance of the obtained results was determined at the 5% level. The student t-test for normally distributed quantitative variables was used to compare the two groups studied. Results: Statistically significant differences in wettability condition discrepancies were found between groups (I) and (II) (p < 0.05). In addition, there were statistically significant differences in intraoral scan body (ISB) length between the two groups (p < 0.05). Regarding the intraoral scan body material, statistically significant differences were found between the two groups (p < 0.05). Conclusions: The presence of saliva significantly affects the accuracy of the digital implant transfer. Additionally, using a longer intraoral scan body improves the accuracy of digital implant impressions. The titanium scan body had a greater level of precision on the implant impression scan.Keywords
Funding Information
- Tanta University
This publication has 29 references indexed in Scilit:
- Improved scanning accuracy with newly designed scan bodies: An in vitro study comparing digital versus conventional impression techniques for complete‐arch implant rehabilitationClinical Oral Implants Research, 2020
- Do Type and Shape of Scan Bodies Affect Accuracy and Time of Digital Implant Impressions?European Journal of Prosthodontics and Restorative Dentistry, 2020
- Impact of Different Scan Bodies and Scan Strategies on the Accuracy of Digital Implant Impressions Assessed with an Intraoral Scanner: An In Vitro StudyJournal of Prosthodontics, 2019
- Clinical Factors Influence the Trueness of Intra-oral ScanningEuropean Journal of Prosthodontics and Restorative Dentistry, 2019
- The accuracy of different dental impression techniques for implant‐supported dental prostheses: A systematic review and meta‐analysisClinical Oral Implants Research, 2018
- A comparison of the accuracy of intraoral scanners using an intraoral environment simulatorThe Journal of Advanced Prosthodontics, 2018
- An In Vitro Study of Factors Influencing the Performance of Digital Intraoral Impressions Operating on Active Wavefront Sampling Technology with Multiple Implants in the Edentulous MaxillaJournal of Prosthodontics, 2016
- Full‐arch implant fixed prostheses: a comparative study on the effect of connection type and impression technique on accuracy of fitClinical Oral Implants Research, 2015
- Digital versus conventional implant impressions for edentulous patients: accuracy outcomesClinical Oral Implants Research, 2015