Comparison of Clinical and Angiographic Outcomes After Saphenous Vein Graft Angioplasty Using Coronary Versus ‘Biliary’ Tubular Slotted Stents
Authors:
- 15 January 1995
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 91 (2) , 339-350
Abstract
Background Saphenous vein graft (SVG) angioplasty using 15-mm articulated, tubular slotted stents results in low (0% to 20%) residual diameter stenoses and infrequent (Methods and Results During a 3-year period, 231 patients with 305 SVG lesions were treated using Palmaz-Schatz coronary (n=108) or biliary (n=123) stents. Cineangiograms were reviewed using qualitative morphological and quantitative angiographic methods. Time-dependent clinical outcome (freedom from death, Q-wave myocardial infarction, or the need for repeat coronary bypass surgery or SVG angioplasty) was assessed using Kaplan-Meier life-table methods. Unstable angina ( P <.001) and recent myocardial infarction ( P =.001) were present more often in patients undergoing biliary stent versus coronary stent placement. Biliary stent–treated SVG lesions were more frequently de novo ( P =.001), ostial in location ( P =.002), ≥10 mm in length ( P =.009), thrombus containing ( P =.001), and ulcerated ( P <.001) than coronary stent–treated SVG lesions. Angiographically, biliary stent–treated lesions had larger reference vessel diameter (3.43±0.59 mm versus 3.10±0.64 mm, P <.001), higher balloon-to-artery ratio (1.15±0.16 mm versus 1.07±0.19, P =.0001), and lower residual diameter stenosis (6±17% versus 14±11% in coronary stent–treated patients; P <.001). Procedural success rates were high (95%), in-hospital major complications were uncommon (Conclusions Despite frequent short-term ischemic syndromes and unfavorable lesion characteristics, both biliary and coronary cohorts have similarly favorable short-term procedural results and long-term clinical outcomes. The increased strut thickness of the biliary stent confers greater fluoroscopic visibility and radial compressive strength in exchange for decreased stent flexibility and added technical demand in stent deployment. Extreme caution is recommended with biliary stent placement in the treatment of SVG lesions as clinical results are highly operator dependent.Keywords
This publication has 31 references indexed in Scilit:
- Investigational use of the Palmaz-Schatz biliary stent in large saphenous vein graftsThe American Journal of Cardiology, 1993
- Results of coronary angioplasty using the transluminal extraction catheterThe American Journal of Cardiology, 1992
- Results of directional atherectomy of primary atheromatous and restenosis lesions in coronary arteries and saphenous vein graftsThe American Journal of Cardiology, 1992
- Palmaz-Schatz stent implantation in stenosed saphenous vein grafts: Clinical and angiographic follow-upAmerican Heart Journal, 1992
- Intracoronary thrombolysis followed by directional atherectomy: A combined approach for thrombotic vein graft lesions considered unsuitable for angioplastyCatheterization and Cardiovascular Diagnosis, 1992
- Quantitative angiographic follow-up of the coronary Wallstent in native vessels and bypass grafts (European experience — March 1986 to March 1990)The American Journal of Cardiology, 1992
- Comparison by quantitative angiographic assessment of coronary stenoses of one view showing the severest narrowing to two orthogonal viewsThe American Journal of Cardiology, 1989
- Nonoperative management of aortocoronary saphenous vein graft rupture during percutaneous transluminal coronary angioplastyThe American Journal of Cardiology, 1987
- Percutaneous transluminal angioplasty of stenotic coronary artery bypass grafts: 5 years' experienceJACC, 1987
- Distal embolization of a coronary artery bypass graft atheroma during percutaneous transluminal coronary angioplastyThe American Journal of Cardiology, 1984