Combined System for Harmonic Suppression and Reactive Power Compensation
Authors:
- An LuoALAn Luo
- Zhikang ShuaiZSZhikang Shuai
- Wenji ZhuWZWenji Zhu
- Z. John ShenZSZ. John Shen
- 2 December 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 56 (2) , 418-428
Abstract
In this paper, a combined system of static Var compensator (SVC) and active power filter (APF) was proposed. The system has the function of power factor correction, voltage stability, and harmonic suppression. The SVC, which consists of delta-connected thyristor-controlled reactor (TCR) and Y-connected passive power filter (PPF), is mainly for voltage stability and power factor correction. The small rating APF is used to filter harmonics generated by the nonlinear load and the TCR in the SVC and to suppress possible resonance between the grid and the PPFs. The configuration and principle of the combined system were discussed first, and then, the control method of the combined system was presented. An optimal nonlinear proportional-integral control was proposed to improve the dynamic response and decrease the steady-state error of the SVC. Harmonic detection with precompensation method and improved generalized integrator control were proposed to improve the performance of APF. The new combined system is compared to classical SVC. It is implemented in a 200-kVA prototype in the laboratory. Simulation and experimental results show that the proposed combined configuration can effectively stabilize system voltage, correct power factor, and suppress harmonic currents.Keywords
This publication has 28 references indexed in Scilit:
- A Novel Three-Phase Hybrid Active Power Filter With a Series Resonance Circuit Tuned at the Fundamental FrequencyIEEE Transactions on Industrial Electronics, 2009
- Model Reference Adaptive Control Design for a Shunt Active-Power-Filter SystemIEEE Transactions on Industrial Electronics, 2008
- Instantaneous Reactive Power Theory Applied to Active Power Filter Compensation: Different Approaches, Assessment, and Experimental ResultsIEEE Transactions on Industrial Electronics, 2008
- A Novel SVC Allocation Method for Power System Voltage Stability Enhancement by Normal Forms of DiffeomorphismIEEE Transactions on Power Systems, 2007
- Performance Analysis of SVCIEEE Transactions on Circuits and Systems for Video Technology, 2007
- Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditionsIEEE Transactions on Industry Applications, 2002
- Hybrid solutions for improving passive filter performance in high power applicationsIEEE Transactions on Industry Applications, 1997
- Analysis of a static VAr compensator using the dispatcher training simulatorIEEE Transactions on Power Systems, 1995
- Advanced SVC control for damping power system oscillationsIEEE Transactions on Power Systems, 1991
- Effective Application of Static Var Compensators to Damp OscillationsIEEE Transactions on Power Apparatus and Systems, 1985