Reproducibility and Side Differences of Mechanical Tests for Determining the Structural Strength of the Proximal Femur
Authors:
- 1 March 2004
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 19 (3) , 379-385
Abstract
In this experimental study, we evaluated the reproducibility error of mechanical strength tests of the proximal femur when simulating a fall on the trochanter. Based on side differences in femoral failure loads in 55 pairs of femora, we estimated the upper limit of the precision error to be 15% for the side impact test, whereas the intersubject variability was >40%. Introduction: Mechanical tests are commonly used as the gold standard for determining one of the main functions of bones, that is, to provide mechanical strength. However, it is unknown what magnitude of error is associated with these tests. Here we investigate the precision error and side difference of a side impact test of the proximal femur. Materials and Methods: BMC was measured using DXA in 54 pairs of femora from donors 79.0 ± 10.6 years of age. Bones were tested to failure, simulating a fall on the greater trochanter. Results: Failure loads were 3951 ± 1659N (CV% = 42%) on the right and 3900 ± 1652N (CV% = 42%) on the left (no significant side difference). The average random difference of femoral BMC was 7 ± 7% and that of femoral failure loads was 17 ± 12%. The correlation between BMC and failure load was 79% (r2), but the association between side differences in failure load with those in BMC was only 4%. When confining the analysis to pairs with less than 5% differences in BMC (n = 31), side differences in failure loads were 15 ± 13%. When correcting failure loads for side differences of BMC, the difference was 16 ± 15% Conclusions: These results suggest that the upper limit of the precision error for femoral strength tests is ∼15% in a side impact configuration. Given the large intersubject variability of failure loads, this test provides an efficient tool for determining the structural strength of the proximal femur in a fall.Keywords
This publication has 58 references indexed in Scilit:
- Bone Strength at Clinically Relevant Sites Displays Substantial Heterogeneity and Is Best Predicted From Site-Specific Bone DensitometryJournal of Bone and Mineral Research, 2002
- The genetics and evolution of handedness.Psychological Review, 1997
- Medical Expenditures for the Treatment of Osteoporotic Fractures in the United States in 1995: Report from the National Osteoporosis FoundationJournal of Bone and Mineral Research, 1997
- A prospective study on socioeconomic aspects of fracture of the proximal femurJournal of Bone and Mineral Research, 1996
- Prediction of fracture load at different skeletal sites by geometric properties of the cortical shellJournal of Bone and Mineral Research, 1996
- Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniquesOsteoporosis International, 1995
- Effects of loading rate on strength of the proximal femurCalcified Tissue International, 1994
- Hip fractures in the elderly: A world-wide projectionOsteoporosis International, 1992
- Prediction of Femoral Impact Forces in Falls on the HipJournal of Biomechanical Engineering, 1991
- Functional asymmetry in the lower limbsCells Tissues Organs, 1970