Universal Digital Controller for Boost CCM Power Factor Correction Stages Based on Current Rebuilding Concept
Open Access
- 5 September 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 29 (7) , 3818-3829
Abstract
Continuous conduction mode power factor correction (PFC) without input current measurement is a step forward with respect to previously proposed PFC digital controllers. Inductor volt-second (vsL) measurement in each switching period enables digital estimation of the input current; however, an accurate compensation of the small errors in the measured vsL is required for the estimation to match the actual current. Otherwise, they are accumulated every switching period over the half-line cycle, leading to an appreciable current distortion. A vsL estimation method is proposed, measuring the input (vg) and output voltage (vo). Discontinuous conduction mode (DCM) occurs near input line zero crossings and is detected by measuring the drain-to-source MOSFET voltage vds. Parasitic elements cause a small difference between the estimated voltage across the inductor based on input and output voltage measurements and the actual one, which must be taken into account to estimate the input current in the proposed sensorless PFC digital controller. This paper analyzes the current estimation error caused by errors in the ON-time estimation, voltage measurements, and the parasitic elements. A new digital feedback control with high resolution is also proposed. It cancels the difference between DCM operation time of the real input current, (TDCMg) and the estimated DCM time (TDCMreb). Therefore, the current estimation is calibrated using digital signals during operation in DCM. A fast feedforward coarse time error compensation is carried out with the measured delay of the drive signal, and a fine compensation is achieved with a feedback loop that matches the estimated and real DCM time. The digital controller can be used in universal applications due to the ability of the DCM time feedback loop to autotune based on the operation conditions (power level, input voltage, output voltage...), which improves the operation range in comparison with previous solutions. Experimental results are shown for a 1-kW boost PFC converter over a wide power and voltage range.Keywords
This publication has 27 references indexed in Scilit:
- Modeling of a high resolution DCM times feedback loop for Sensorless Boost PFC stages2013
- High-resolution error compensation in continuous conduction mode power factor correction stage without current sensor2012
- Current error compensation for current-sensorless power factor corrector stage in continuous conduction mode2012
- Voltage sensorless feedforward control of a dual boost PFC converter for battery charger applications2011
- Self-Tuning Digital Current Estimator for Low-Power Switching Converters2008
- A Digital Power Factor Correction (PFC) Control Strategy Optimized for DSPIEEE Transactions on Power Electronics, 2004
- A novel technique to achieve unity power factor and fact transient response in AC-to-DC convertersIEEE Transactions on Power Electronics, 2001
- Sensorless current mode control-an observer-based technique for DC-DC convertersIEEE Transactions on Power Electronics, 2001
- Fundamentals of Power Electronics2001
- Nonlinear-carrier control for high-power-factor boost rectifiersIEEE Transactions on Power Electronics, 1996