Adjustment of Single Continuous Suture to Control Astigmatism After Penetrating Keratoplasty
Authors:
- Izak F WesselsIWIzak F Wessels
- 1 July 1989
- journal article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 5 (4) , 216-223
Abstract
The presence of high amounts of regular and irregular astigmatism after penetrating keratoplasty has been a major challenge for corneal surgeons. We have devised a technique of suture adjustment which redistributes the tension in a single continuous 10-0 nylon suture according to keratometric findings and overcomes some of the limitations of other published methods for reducing penetrating keratoplasty astigmatism. Suture adjustment Is performed at the slit-lamp microscope using topical anesthesia, from as early as the first postoperative day. The effects are controllable, reversible, stable, and can achieve relaxation or tightening of any meridian. Of 330 consecutive eyes undergoing penetrating keratoplasty, 205 required and underwent one or more suture adjustments. The mean keratometric astigmatism after suture adjustment was 2.87 D (SD=187), compared to a preceding consecutive series of 136 eyes without suture adjustment with 4.80 D (SD =3.13) mean astigmatism (P< 0.0001). This effect persisted even when the suture had to be removed (P<0.0001). Infection did not occur. Only five eyes (2.4%) experienced a broken suture, which was readily spliced. We recommend adjustment of a single continuous suture, when moderate to severe astigmatism is present after a penetrating keratoplasty. [Refractive and Corneal Surgery 1989; 5:216-223.]Keywords
This publication has 12 references indexed in Scilit:
- The Effect of Suture Removal on Postkeratoplasty AstigmatismAmerican Journal of Ophthalmology, 1988
- PREVENTION OF ASTIGMATISM IN CORNEAL TRANSPLANT SURGERYInternational Ophthalmology Clinics, 1988
- Relaxing Keratotomy for Post-Keratoplasty High AstigmatismOphthalmic Surgery, Lasers and Imaging Retina, 1983
- Disparate Diameter GraftingOphthalmology, 1981
- Current Techniques for Improved Visual Results After Penetrating KeratoplastyOphthalmic Surgery, Lasers and Imaging Retina, 1981
- An Analysis and Interpretation of Refractive Errors after Penetrating KeratoplastyOphthalmology, 1981
- Thermal Wedge with Penetrating Keratoplasty to Reduce High Corneal CylinderAmerican Journal of Ophthalmology, 1980
- Surgical Correction of High Postkeratoplasty AstigmatismArchives of Ophthalmology (1950), 1980
- Eye Surgery1980
- Die Richtung der Hauptmeridiane des astigmatischen AugesGraefe's Archive for Clinical and Experimental Ophthalmology, 1869