Percutaneous antegrade screwing for anterior column fracture of acetabulum with fluoroscopic-based computerized navigation
- 13 June 2007
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 128 (2) , 223-226
Abstract
Introduction Open reduction and internal fixation has been the gold standard for displaced fracture involving weightbearing dome and fractures with intra-articular fragments. However, extensile exposure can lead to complications. Fracture with minimal displacement can be fixed by a minimally invasive method. Percutaneous screwing for an anterior column fracture of acetabulum under conventional 2D fluoroscopy is a demanding technique. With fluoroscopic-based computerized navigation, we can determine the position of a screw real time intra-operatively with less exposure to radiation. We proposed that a fluoroscopy-based computerized navigational system would simplify operation procedures. The purpose of this study is to test the application of the fluoroscopy-based computerized navigational system for anterior column fracture of acetabulum. Materials and methods A prospective cohort study was conducted. Three patients with mildly displaced or non-displaced anterior column fracture of acetabulum were treated with a retrograde lag screw under a fluoroscopy-based computer navigation system. There were two males and one female with a mean age of 39 years and all patients were followed up for more than 1 year. Patients were allowed to perform joint movement exercises and to walk with partial weightbearing on the first day post-operatively. Results The mean operation time was 40 min (range 30–45 min) from the use of fluoroscopy to wound closure and the mean total fluoroscopy time was 38 s (range 35–45 s). Total blood loss was less than 10 ml. The patients were pain free 1 week after the operation and had good functional recovery thereafter. No complication was noted postoperatively. Conclusion Though the indication for this procedure is limited, we think that there should be potential to apply the screw with less radiation by fluoroscopic-based computerized navigation. Once anatomic reduction can be achieved by the close method in the anterior column fracture of the acetabulum, percutaneous screw fixation under fluoroscopic-based computerized navigation could be a reliable method; however; validating the position of the guide pin and screw by fluoroscopy is suggested.Keywords
This publication has 12 references indexed in Scilit:
- Percutaneous retrograde screwing for stabilisation of acetabular fracturesInjury, 2005
- First Generation Computerized Fluoroscopic Navigation in Percutaneous Pelvic SurgeryJournal of Orthopaedic Trauma, 2004
- Closed Reduction and Percutaneous Fixation of Anterior Column Acetabular FracturesComputer Aided Surgery, 2002
- Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the actabulumInjury, 2001
- Intraoperative Fluoroscopy to Evaluate Fracture Reduction and Hardware Placement During Acetabular SurgeryJournal of Orthopaedic Trauma, 1999
- Letter to the EditorJournal of Orthopaedic Trauma, 1998
- Preliminary Report: The Retrograde Medullary Superior Pubic Ramus Screw for the Treatment of Anterior Pelvic Ring Disruptions: A New TechniqueJournal of Orthopaedic Trauma, 1995
- Percutaneous screw fixation of acetabular fractures with CT guidance: preliminary results of a new technique.American Journal of Roentgenology, 1992
- Displaced Acetabular FracturesClinical Orthopaedics and Related Research, 1988
- Acetabulum FracturesClinical Orthopaedics and Related Research, 1980