Performance Evaluation of a Novel Sample In–Answer Out (SIAO) System Based on Magnetic Nanoparticles
- 1 December 2017
- journal article
- research article
- Published by American Scientific Publishers in Journal of Biomedical Nanotechnology
- Vol. 13 (12) , 1619-1630
Abstract
In recent years, the prevention, control, diagnosis and treatment of infectious diseases has become a global focus for public health. Traditional methods for pathogen testing have some major disadvantages including the need for highly skilled staff and expensive instrumentation, while procedural aspects are complex and sensitive to the environment. These shortcomings have greatly limited the application of traditional testing in on site pathogen detection. In this paper, we present a new point-of-care-testing (POCT) system based on magnetic nanoparticles that enable sample in–answer out (SIAO) automated real-time testing for pathogens. Various performance tests were conducted on the instrument. Nucleic acid extraction efficiencies of SIAO versus manual systems were 95.49% and 84.33%, respectively. Real-time PCR by two methods (TaqMan-based probe and SYBR green dye) in the SIAO system was achievable, with comparable results to the manual method. Nucleic acid testing with the SIAO system was repeatable and better than with manual testing. The SIAO system had good anti-pollution performance with easy avoidance of inter-assay cross contamination. Finally, use of the SIAO system for adenovirus detection produced similar results to LightCycler2.0 system assay findings. The amplification plots and Ct values suggested similar amplification plots shapes for adenovirus testing with the SIAO system and with real-time fluorescence PCR testing and commercial instrument post-manual nucleic acid extraction. Collectively, these findings indicate that testing with the SIAO system is virtually equivalent to that of manual extraction with commercial system testing.Keywords
This publication has 98 references indexed in Scilit:
- New nucleic acid testing devices to diagnose infectious diseases in resource-limited settingsEuropean Journal of Clinical Microbiology & Infectious Diseases, 2017
- Synthesis of aptamer-functionalized Ag nanoclusters for MCF-7 breast cancer cells imagingScience China Chemistry, 2016
- A new method for improving the accuracy of miRNA detection with NaYF4:Yb,Er upconversion nanoparticlesScience China Chemistry, 2016
- Development of a monoclonal antibody-based enzyme-linked immunosorbent assay for luteoloside detection in Flos Lonicerae JaponicaeAnalytical and Bioanalytical Chemistry, 2016
- Applications of aptamers for chemistry analysis, medicine and food securityScience China Chemistry, 2015
- Potential of cross-priming amplification and DNA-based lateral-flow strip biosensor for rapid on-site GMO screeningAnalytical and Bioanalytical Chemistry, 2014
- Sample Pretreatment and Nucleic Acid-Based Detection for Fast Diagnosis Utilizing Microfluidic SystemsAnnals of Biomedical Engineering, 2011
- A portable, integrated analyzer for microfluidic – based molecular analysisBiomedical Microdevices, 2011
- An integrated, self-contained microfluidic cassette for isolation, amplification, and detection of nucleic acidsBiomedical Microdevices, 2010
- Finger-actuated, self-contained immunoassay cassettesBiomedical Microdevices, 2009