Abstract
Microdialysis sampling is an important tool for chemical monitoring in living systems. Temporal resolution is an important figure of merit that is determined by sampling frequency, assay sensitivity, and dispersion of chemical zones during transport from sampling device to fraction collector or analytical system. Temporal resolution has recently been improved by segmenting flow into plugs, so that nanoliter fractions are collected at intervals of 0.1–2 s, thus eliminating temporal distortion associated with dispersion in continuous flow. Such systems, however, have yet to be used with behaving subjects. Furthermore, long-term storage of nanoliter samples created by segmented flow has not been reported. In this work, we have addressed these challenges. A microdialysis probe was integrated to a plug generator that could be stably mounted onto behaving animals. Long-term storage of dialysate plugs was achieved by collecting plugs into high-purity perfluoroalkoxy tubes, placing the tube into hexane and then freezing at −80°C. Slow warming with even temperatures prevented plug coalescence during sample thawing. As a demonstration of the system, plugs were collected from the striatum of behaving rats using a 0.5-mm-long microdialysis probe. Resulting plugs were analyzed 1–4 days later by chip-based electrophoresis. To improve throughput of plug analysis over previous work, the speed of electrophoretic separation was increased by using forced air cooling and 1-butyl-2,3-dimethylimidazolium tetrafluoroborate as a separation buffer additive, allowing resolution of six neuroactive amino acids in 30 s. Concentration changes induced by K+ microinjections were monitored with 10 s temporal resolution. The improvements reported in this work make it possible to apply segmented flow microdialysis to the study of behaving animals and enable experiments where the analytical system cannot be placed close to the animal.Keywords
This publication has 34 references indexed in Scilit:
- Improved Temporal Resolution for in Vivo Microdialysis by Using Segmented FlowAnalytical Chemistry, 2008
- Application Of Rapid-Sampling, Online Microdialysis To The Monitoring Of Brain Metabolism During Aneurysm SurgeryOperative Neurosurgery, 2006
- In Vivo Measurements of Neurotransmitters by Microdialysis SamplingAnalytical Chemistry, 2006
- Transient changes in nucleus accumbens amino acid concentrations correlate with individual responsivity to the predator fox odor 2,5‐dihydro‐2,4,5‐trimethylthiazolineJournal of Neurochemistry, 2005
- High temporal resolution for in vivo monitoring of neurotransmitters in awake epileptic rats using brain microdialysis and capillary electrophoresis with laser-induced fluorescence detectionJournal of Neuroscience Methods, 2004
- On-Line Coupling of Microdialysis Sampling with Microchip-Based Capillary ElectrophoresisAnalytical Chemistry, 2004
- One-second time resolution brain microdialysis in fully awake ratsProtocol for the collection, separation and sorting of nanoliter dialysate volumesJournal of Chromatography B, 2003
- In vivo microdialysis as a tool for monitoring pharmacokineticsTrAC Trends in Analytical Chemistry, 2000
- Trace-Level Amino Acid Analysis by Capillary Liquid Chromatography and Application to in Vivo Microdialysis Sampling with 10-s Temporal ResolutionAnalytical Chemistry, 2000
- High Temporal Resolution Monitoring of Glutamate and Aspartate in Vivo Using Microdialysis On-Line with Capillary Electrophoresis with Laser-Induced Fluorescence DetectionAnalytical Chemistry, 1997