Estimation of central aortic pressure waveform features derived from the brachial cuff volume displacement waveform
- 1 August 2012
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2012 (1094687X) , 2591-2594
Abstract
There is increasing interest in non-invasive estimation of central aortic waveform parameters in the clinical setting. However, controversy has arisen around radial tonometric based systems due to the requirement of a trained operator or lack of ease of use, especially in the clinical environment. A recently developed device utilizes a novel algorithm for brachial cuff based assessment of aortic pressure values and waveform (SphygmoCor XCEL, AtCor Medical). The cuff was inflated to 10 mmHg below an individual's diastolic blood pressure and the brachial volume displacement waveform recorded. The aortic waveform was derived using proprietary digital signal processing and transfer function applied to the recorded waveform. The aortic waveform was also estimated using a validated technique (radial tonometry based assessment, SphygmoCor, AtCor Medical). Measurements were taken in triplicate with each device in 30 people (17 female) aged 22 to 79 years of age. An average for each device for each individual was calculated, and the results from the two devices were compared using regression and Bland-Altman analysis. A high correlation was found between the devices for measures of aortic systolic (R 2 =0.99) and diastolic (R 2 =0.98) pressure. Augmentation index and subendocardial viability ratio both had a between device R 2 value of 0.82. The difference between devices for measured aortic systolic pressure was 0.5±1.8 mmHg, and for augmentation index, 1.8±7.0%. The brachial cuff based approach, with an individualized sub-diastolic cuff pressure, provides an operator independent method of assessing not only systolic pressure, but also aortic waveform features, comparable to existing validated tonometric-based methods.Keywords
This publication has 18 references indexed in Scilit:
- The Impact of Cardiovascular Risk Factors on Aortic Stiffness and Wave Reflections Depends on AgeHypertension, 2010
- A new oscillometric method for pulse wave analysis: comparison with a common tonometric methodJournal of Human Hypertension, 2010
- Validity and repeatability of the Vicorder apparatus: a comparison with the SphygmoCor deviceHypertension Research, 2009
- Comparison of aortic pulse wave velocity measured by three techniques: Complior, SphygmoCor and ArteriographJournal Of Hypertension, 2008
- Central Pressure More Strongly Relates to Vascular Disease and Outcome Than Does Brachial PressureHypertension, 2007
- Estimation of central pressure augmentation using automated radial artery tonometryJournal Of Hypertension, 2007
- Response to Letters Regarding Article, “Differential Impact of Blood Pressure-Lowering Drugs on Central Aortic Pressure and Clinical Outcomes: Principal Results of the Conduit Artery Function Evaluation (CAFE) Study”Circulation, 2006
- Prospective Evaluation of a Method for Estimating Ascending Aortic Pressure From the Radial Artery Pressure WaveformHypertension, 2001
- Validation of Carotid Artery Tonometry as a Means of Estimating Augmentation Index of Ascending Aortic PressureHypertension, 1996
- The myocardial supply:Demand ratio—A critical reviewThe American Journal of Cardiology, 1978