Measuring Particulate Emissions of Light Duty Passenger Vehicles Using Integrated Particle Size Distribution (IPSD)
Authors:
- 16 April 2015
- journal article
- research article
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 49 (9) , 5618-5627
Abstract
The California Air Resources Board (ARB) adopted the low emission vehicle (LEV) III particulate matter (PM) standards in January 2012, which require, among other limits, vehicles to meet 1 mg/mi over the federal test procedure (FTP). One possible alternative measurement approach evaluated to support the implementation of the LEV III standards is integrated particle size distribution (IPSD), which reports real-time PM mass using size distribution and effective density. The IPSD method was evaluated using TSI’s engine exhaust particle sizer (EEPS, 5.6–560 nm) and gravimetric filter data from more than 250 tests and 34 vehicles at ARB’s Haagen-Smit Laboratory (HSL). IPSD mass was persistently lower than gravimetric mass by 56–75% over the FTP tests and by 81–84% over the supplemental FTP (US06) tests. Strong covariance between the methods suggests test-to-test variability originates from actual vehicle emission differences rather than measurement accuracy, where IPSD offered no statistical improvement over gravimetric measurement variability.Keywords
This publication has 42 references indexed in Scilit:
- Comparability of mobility particle sizers and diffusion chargersJournal of Aerosol Science, 2013
- Observation of elevated air pollutant concentrations in a residential neighborhood of Los Angeles California using a mobile platformAtmospheric Environment, 2012
- The Mobility of Fractal Aggregates: A ReviewAerosol Science and Technology, 2011
- Particulate Matter Air Pollution and Cardiovascular DiseaseCirculation, 2010
- Effect of Advanced Aftertreatment for PM and NOx Control on Heavy-Duty Diesel Truck EmissionsEnvironmental Science & Technology, 2009
- Inter-Comparison of a Fast Mobility Particle Sizer and a Scanning Mobility Particle Sizer Incorporating an Ultrafine Water-Based Condensation Particle CounterAerosol Science and Technology, 2009
- Climate change and health costs of air emissions from biofuels and gasolineProceedings of the National Academy of Sciences, 2009
- Studies of Diesel Engine Particle Emissions During Transient Operations Using an Engine Exhaust Particle SizerAerosol Science and Technology, 2006
- Surface science with nanosized particles in a carrier gasJournal of Vacuum Science & Technology A, 2001
- Examination of the Size-Resolved and Transient Nature of Motor Vehicle Particle EmissionsEnvironmental Science & Technology, 1999