Geometric accuracy of magnetic resonance imaging–derived virtual 3‐dimensional bone surface models of the mandible in comparison to computed tomography and cone beam computed tomography: A porcine cadaver study
Open Access
- 27 July 2021
- journal article
- research article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 23 (5) , 779-788
Abstract
Background: Providing accurate 3‐dimensional virtual bone surface models is a prerequisite for virtual surgical planning and additive manufacturing in craniomaxillofacial surgery. For this purpose, magnetic resonance imaging (MRI) may be a radiation‐free alternative to computed tomography (CT) and cone beam computed tomography (CBCT).Purpose: The aim of this study was to assess the geometric accuracy of 3‐dimensional T1‐weighted MRI‐derived virtual bone surface models of the mandible in comparison to CT and CBCT.Materials and methods: Specimens of the mandible from porcine cadavers were scanned with (1) a 3‐dimensional T1‐weighted MRI sequence (0.6 mm isotropic voxel) optimized for bone imaging, (2) CT, and (3) CBCT. Cortical mandibular structures (n = 10) were segmented using semiautomated and manual techniques. Imaging‐based virtual 3‐dimensional models were aligned with a high‐resolution optical 3‐dimensional surface scan of the dissected bone (=ground truth) and global geometric deviations were calculated (mean surface distance [MSD]/root‐mean‐square distance [RMSD]). Agreement between the imaging modalities was assessed by equivalence testing and Bland–Altman analysis.Results: Intra‐ and inter‐rater agreement was on a high level for all modalities. Global geometric deviations (MSD/RMSD) between optical scans and imaging modalities were 0.225 ± 0.020 mm/0.345 ± 0.074 mm for CT, 0.280 ± 0.067 mm/0.371 ± 0.074 mm for MRI, and 0.352 ± 0.076 mm/0.454 ± 0.071 mm for CBCT. All imaging modalities were statistically equivalent within an equivalence margin of ±0.3 mm, and Bland–Altman analysis indicated high agreement as well.Conclusions: The results of this study indicate that the accuracy and reliability of MRI‐derived virtual 3‐dimensional bone surface models is equal to CT and CBCT. MRI may be considered as a reliable alternative to CT and CBCT in computer‐assisted craniomaxillofacial surgery.Keywords
This publication has 55 references indexed in Scilit:
- Three-Dimensional Computer-Assisted Surgical Planning, Manufacturing, Intraoperative Navigation, and Computed Tomography in Maxillofacial TraumaAtlas of the Oral and Maxillofacial Surgery Clinics, 2020
- Computer-Aided Planning and Placement in Implant SurgeryAtlas of the Oral and Maxillofacial Surgery Clinics, 2020
- Improved scan method for dental imaging using multidetector computed tomography: a phantom studyDentomaxillofacial Radiology, 2020
- Digital Workflow for Combined Orthodontics and Orthognathic SurgeryOral and Maxillofacial Surgery Clinics of North America, 2020
- Dental X-Rays and the Risk of Thyroid Cancer and Meningioma: A Systematic Review and Meta-Analysis of Current Epidemiological EvidenceThyroid®, 2019
- Virtual 3D planning of osteotomies for craniosynostoses and complex craniofacial malformationsNeurochirurgie, 2019
- Novel low-dose protocols using cone beam computed tomography in dental medicine: a review focusing on indications, limitations, and future possibilitiesClinical Oral Investigations, 2019
- The accuracy of static computer‐aided implant surgery: A systematic review and meta‐analysisClinical Oral Implants Research, 2018
- Accuracy of computer-assisted surgery in mandibular reconstruction: A systematic reviewOral Oncology, 2018
- Diagnostic X-Ray Exposure and Thyroid Cancer Risk: Systematic Review and Meta-AnalysisThyroid®, 2018