The adaptability of the Pulsta valve to the diverse main pulmonary artery shape of native right ventricular outflow tract disease
- 11 February 2024
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 103 (4) , 587-596
Abstract
Background: Pulsta valve is increasingly used for percutaneous pulmonary valve implantation (PPVI) in patients with a large native right ventricular outflow tract (RVOT). This study aims to elucidate the outcomes of Pulsta valve implantation within the native RVOT and assess its adaptability to various native main pulmonary artery (PA) anatomies.Methods: A multicenter retrospective study included 182 patients with moderate to severe pulmonary regurgitation in the native RVOT who underwent PPVI with Pulsta valves® between February 2016 and August 2023 at five Korean and Taiwanese tertiary referral centers.Results: Pulsta valve implantation was successful in 179 out of 182 patients (98.4%) with an average age of 26.7 ± 11.0 years. The median follow‐up duration was 29 months. Baseline assessments revealed enlarged right ventricle (RV) volume (mean indexed RV end‐diastolic volume: 163.1 (interquartile range, IQR: 152.0–180.3 mL/m²), which significantly decreased to 123.6(IQR: 106.6–137.5 mL/m2 after 1 year. The main PA types were classified as pyramidal (3.8%), straight (38.5%), reverse pyramidal (13.2%), convex (26.4%), and concave (18.1%) shapes. Pulsta valve placement was adapted, with distal main PA for pyramidal shapes and proximal or mid‐PA for reverse pyramidal shapes. Two patients experienced Pulsta valve embolization to RV, requiring surgical removal, and one patient encountered valve migration to the distal main PA, necessitating surgical fixation.Conclusions: Customized valve insertion sites are pivotal in self‐expandable PPVI considering diverse native RVOT shape. The rather soft and compact structure of the Pulsta valve has characteristics to are adaptable to diverse native RVOT geometries.Keywords
All Related Versions
This publication has 25 references indexed in Scilit:
- Mid‐term outcomes of the Pulsta transcatheter pulmonary valve for the native right ventricular outflow tractCatheterization and Cardiovascular Interventions, 2021
- 2018 AHA/ACC Guideline for the Management of Adults With Congenital Heart DiseaseJACC, 2019
- Safety and Feasibility of Melody Transcatheter Pulmonary Valve Replacement in the Native Right Ventricular Outflow TractJACC: Cardiovascular Interventions, 2018
- Early outcomes of percutaneous pulmonary valve implantation using the Edwards SAPIEN XT transcatheter heart valve systemInternational Journal of Cardiology, 2018
- Harmony Feasibility TrialJACC: Cardiovascular Interventions, 2017
- Early experience with the Venus p‑valve for percutaneous pulmonary valve implantation in native outflow tractNetherlands Heart Journal, 2016
- Percutaneous Pulmonary Valve ImplantationJACC, 2015
- Hybrid Approach for Off-Pump Pulmonary Valve Replacement in Patients With a Dilated Right Ventricular Outflow TractThe Annals of Thoracic Surgery, 2015
- Early clinical experience with a novel self‐expanding percutaneous stent‐valve in the native right ventricular outflow tractCatheterization and Cardiovascular Interventions, 2014
- Outcomes and safety of transcatheter pulmonary valve replacement in patients with large patched right ventricular outflow tractsArchives of Cardiovascular Diseases, 2012