Combining distance and anatomical information for deep-learning based dose distribution predictions for nasopharyngeal cancer radiotherapy planning
Authors:
Open Access
- 28 February 2023
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 13, 1041769
Abstract
Purpose: Deep-learning effectively predicts dose distributions in knowledge-based radiotherapy planning. Using anatomical information that includes a structure map and computed tomography (CT) data as input has been proven to work well. The minimum distance from each voxel in normal structures to planning target volume (DPTV) closely affects each voxel’s dose. In this study, we combined DPTV and anatomical information as input for a deep-learning–based dose-prediction network to improve performance.Materials and methods: One hundred patients who underwent volumetric-modulated arc therapy for nasopharyngeal cancer were selected in this study. The prediction model based on a residual network had DPTV maps, structure maps, and CT as inputs and the corresponding dose distribution maps as outputs. The performances of the combined distance and anatomical information (COM) model and the traditional anatomical (ANAT) model with two-channel inputs (structure maps and CT) were compared. A 10-fold cross validation was performed to separately train and test the COM and ANAT models. The voxel-based mean error (ME), mean absolute error (MAE), dosimetric parameters, and dice similarity coefficient (DSC) of isodose volumes were used for modeling evaluation.Results: The mean MAE of the body volume of the COM model were 4.89 ± 1.35%, highly significantly lower than those for the ANAT model of 5.07 ± 1.37% (p<0.001). The ME values of the body for the 2-type models were similar (p >0.05). The mean DSC values of the isodose volumes in the range of 60 Gy were all better in the COM model (pp<0.001). For most organs at risk, the ME, MAE, and dosimetric parameters predicted by both models were concurrent with the ground truth values except the MAE values of the pituitary and optic chiasm in the ANAT model and the average mean dose of the right parotid in the ANAT model.Conclusions: The COM model outperformed the ANAT model and could improve automated planning with statistically highly significant differences.Keywords
This publication has 27 references indexed in Scilit:
- A quality control model that uses PTV-rectal distances to predict the lowest achievable rectum dose, improves IMRT planning for patients with prostate cancerRadiotherapy and Oncology, 2013
- Fully Automated Simultaneous Integrated Boosted–Intensity Modulated Radiation Therapy Treatment Planning Is Feasible for Head-and-Neck Cancer: A Prospective Clinical StudyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Predicting dose‐volume histograms for organs‐at‐risk in IMRT planningMedical Physics, 2012
- Quantitative analysis of the factors which affect the interpatient organ‐at‐risk dose sparing variation in IMRT plansMedical Physics, 2012
- Variations in the Contouring of Organs at Risk: Test Case From a Patient With Oropharyngeal CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Knowledge-based IMRT treatment planning for prostate cancerMedical Physics, 2011
- A planning quality evaluation tool for prostate adaptive IMRT based on machine learningMedical Physics, 2011
- Heart and coronary artery protection in patients with mediastinal Hodgkin lymphoma treated with intensity-modulated radiotherapy: Dose constraints to virtual volumes or to organs at risk?Radiotherapy and Oncology, 2008
- Intensity-Modulated Radiation Therapy Dose Prescription, Recording, and Delivery: Patterns of Variability Among Institutions and Treatment Planning SystemsJNCI: Journal of the National Cancer Institute, 2008
- Multicentre quality assurance of intensity‐modulated radiation therapy plans: A precursor to clinical trialsAustralasian Radiology, 2007