Continuous Glucose Monitoring in Normal Mice and Mice with Prediabetes and Diabetes
Authors:
- 1 June 2006
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 8 (3) , 402-412
Abstract
It is well established that the key to minimizing diabetes-associated complications, in both type 1 and type 2 diabetes, is tight regulation of blood glucose levels. Currently the major approach to regulating blood glucose levels in patients with diabetes relies on external blood glucose monitors. However, poor patient compliance usually results in limited insights into the dynamic range of blood glucose levels (i.e., hyperglycemia vs. hypoglycemia), and inadequate prediction and control of blood glucose levels in these patients. Implantable glucose sensors hold promise for controlling blood glucose levels, but currently these sensors have only limited in vivo life span. Recently we have developed an extremely robust murine model for implantable glucose sensors. In the present study, we have extended this model by developing a complete system for real-time continuous glucose monitoring in normal mice and mice with prediabetes and diabetes (type 1). These studies demonstrated that (1) glucose sensors can be implanted and maintained subcutaneously in the mice; (2) continuous glucose sensor data can be obtained for at least 5 days; and (3) subcutaneous blood glucose sensing paralleled blood glucose levels in normal mice and mice with prediabetes and diabetes. Subcutaneous blood glucose sensing also successfully tracked changes in blood glucose levels induced in the mice with diabetes by administration of oral glucose or insulin. These results mirror the results for subcutaneous blood glucose sensing seen in both normal subjects and patients with diabetes, and therefore validate both our continuous glucose monitoring system in the mouse, and the use of the mouse as a model for implantable glucose sensing in vivo.Keywords
This publication has 16 references indexed in Scilit:
- THE NOD MOUSE: A Model of Immune DysregulationAnnual Review of Immunology, 2005
- Enhancement of implantable glucose sensor function in vivo using gene transfer-induced neovascularizationBiomaterials, 2005
- Accuracy of the Modified Continuous Glucose Monitoring (CGMS ® ) Sensor in an Outpatient Setting: Results from a Diabetes Research in Children Network (DirecNet) StudyDiabetes Technology & Therapeutics, 2005
- Introductory Experience with the Continuous Glucose Monitoring System (CGMS®; Medtronic Minimed®) in Detecting Hyperglycemia by Comparing the Self-Monitoring of Blood Glucose (SMBG) in Non-Pregnant Women and in Pregnant Women with Impaired Glucose Tolerance and Gestational DiabetesExperimental and Clinical Endocrinology & Diabetes, 2004
- Use of vascular endothelial cell growth factor gene transfer to enhance implantable sensor function in vivoJournal of Biomedical Materials Research Part A, 2003
- A Continuous Glucose Sensor Based on Wired Enzyme ™ Technology - Results from a 3-Day Trial in Patients with Type 1 DiabetesDiabetes Technology & Therapeutics, 2003
- Continuous Glucose Monitoring: Reliable Measurements for up to 4 Days with the SCGM1 SystemDiabetes Technology & Therapeutics, 2003
- Accuracy of the continuous glucose monitoring system in inpatient and outpatient conditionsDiabetes & Metabolism, 2003
- Assessment of Chronically Implanted Subcutaneous Glucose Sensors in DogsASAIO Journal, 1999
- Design and Optimization of a Selective Subcutaneously Implantable Glucose Electrode Based on "Wired" Glucose OxidaseAnalytical Chemistry, 1995