Rapid and Simultaneous Determination of 238Pu, 239Pu, 240Pu, and 241Pu in Samples with High-Level Uranium Using ICP-MS/MS and Extraction Chromatography
Authors:
- 17 August 2023
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (34) , 12931-12939
Abstract
As the most important plutonium isotopes, 238Pu, 239Pu, 240Pu, and 241Pu are normally measured by two to three techniques, which are tedious, time-consuming, and not suitable for rapid analysis in emergency situations. Recently, ICP-MS has become a competitive technique for the rapid measurement of 239Pu, 240Pu, and 241Pu. However, ICP-MS is difficult to measure 238Pu due to the serious isobaric interference of 238U. This work reports a rapid analytical method to solve this problem for the simultaneous determination of 238Pu, 239Pu, 240Pu, and 241Pu using triple-quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS) combined with chemical separation. Chemical separation achieved a high decontamination factor of 2.12 × 109 for the most critical interfering element, uranium, by using two sequential TK200 columns. The interferences of 238U1H+ and 238U+ were effectively eliminated by using 12 mL/min He-6 mL/min NH3 as the reaction gases in the octupole collision/reaction cell in ICP-MS/MS. Combined with chemical separation, the overall elimination efficiency of 238U1H+ reached 3.6 × 1017, which is 105 times better than the reported method. With the high 238U+ elimination efficiency of 1.12 × 104 in the ICP-MS/MS measurement, the overall removal efficiency of 238U+ reached 1013, guaranteeing accurate determination of femtogram-level 238Pu as well as 239Pu, 240Pu, and 241Pu in the samples containing milligram-level 238U. The detection time is reduced to minutes, well fulfilling the requirement of rapid analysis. This method is validated by analyzing the standard reference material and the spiked samples.Keywords
Funding Information
- National Natural Science Foundation of China (11875261)
- Chinese Academy of Sciences (132B61KYSB20180003, XDB40020104, ZDBS-SSW-DQC003)
This publication has 33 references indexed in Scilit:
- RAPID DETERMINATION OF 237NP AND PLUTONIUM ISOTOPES IN URINE BY INDUCTIVELY-COUPLED PLASMA MASS SPECTROMETRY AND ALPHA SPECTROMETRYHealth Physics, 2011
- Determination of Transuranium Isotopes (Pu, Np, Am) by Radiometric Techniques: A Review of Analytical MethodologyAnalytical Chemistry, 2011
- Rapid isolation of plutonium in environmental solid samples using sequential injection anion exchange chromatography followed by detection with inductively coupled plasma mass spectrometryAnalytica Chimica Acta, 2011
- High-Throughput Sequential Injection Method for Simultaneous Determination of Plutonium and Neptunium in Environmental Solids Using Macroporous Anion-Exchange Chromatography, Followed by Inductively Coupled Plasma Mass Spectrometric DetectionAnalytical Chemistry, 2010
- Simultaneous uranium/plutonium separation and direct isotope ratio measurements by using CO2 as the gas in a collision/reaction cell based MC-ICPMSJournal of Analytical Atomic Spectrometry, 2010
- Rapid and simultaneous determination of neptunium and plutonium isotopes in environmental samples by extraction chromatography using sequential injection analysis and ICP-MSJournal of Analytical Atomic Spectrometry, 2010
- Determination of 240Pu/239Pu, 241Pu/239Pu and 242Pu/239Pu isotope ratios in environmental reference materials and samples from Chernobyl by thermal ionization mass spectrometry (TIMS) and filament carburizationJournal of Analytical Atomic Spectrometry, 2010
- Determination of plutonium isotopes in waters and environmental solids: A reviewAnalytica Chimica Acta, 2009
- Assessment of plutonium measurement in the femtogram range by ICP-MS; correction from interfering polyatomic speciesJournal of Analytical Atomic Spectrometry, 2007
- Determination of Pu isotope concentrations and isotope ratio by inductively coupled plasma mass spectrometry: a review of analytical methodologyJournal of Analytical Atomic Spectrometry, 2007