On the mechanisms enabling myocardial edema contrast in bSSFP‐based imaging approaches

Authors:

Abstract
The biophysical mechanisms influencing balanced steady‐state free precession (bSSFP) based edema imaging in the setting of acute myocardial infarction are not well understood. To assess the various mechanisms that enable the detection of myocardial edema on bSSFP‐based imaging approaches (cine bSSFP and T2‐prepared bSSFP), experiments were conducted in canine models subjected to ischemia‐reperfusion injury. Results showed that in addition to relaxation effects, the alteration in thermal equilibrium (M0) (including magnetization transfer) has a significant contribution to the image contrast between edematous and healthy myocardium. The relative signal‐intensity ratios between edematous and healthy myocardium were: 1.51 ± 0.18 (cine bSSFP) and 1.58 ± 0.20 (T2‐prepared bSSFP); the theoretically estimated relative relaxation and M0 effects were: 1.17 ± 0.09 and 1.30 ± 0.19, respectively (cine bSSFP), and 1.49 ± 0.23 and 1.06 ± 0.07, respectively (T2‐prepared bSSFP). There were no significant difference between cine bSSFP and T2‐prep bSSFP relative signal‐intensity ratios. However, the relative relaxation effect in cine bSSFP was significantly lower than in T2‐prep bSSFP (P < 0.05), and the M0 effect in cine bSSFP was significantly higher than in T2‐prep bSSFP (P < 0.05). Hence the acquisition strategies that wish to maximize myocardial edema contrast in cine bSSFP imaging should take both relaxation and M0 effects into account. Magn Reson Med, 2011.
Funding Information
  • National Institute of Health Grants (NHLBI HL091989)

This publication has 13 references indexed in Scilit: