On the mechanisms enabling myocardial edema contrast in bSSFP‐based imaging approaches
Open Access
- 9 March 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (1) , 187-191
Abstract
The biophysical mechanisms influencing balanced steady‐state free precession (bSSFP) based edema imaging in the setting of acute myocardial infarction are not well understood. To assess the various mechanisms that enable the detection of myocardial edema on bSSFP‐based imaging approaches (cine bSSFP and T2‐prepared bSSFP), experiments were conducted in canine models subjected to ischemia‐reperfusion injury. Results showed that in addition to relaxation effects, the alteration in thermal equilibrium (M0) (including magnetization transfer) has a significant contribution to the image contrast between edematous and healthy myocardium. The relative signal‐intensity ratios between edematous and healthy myocardium were: 1.51 ± 0.18 (cine bSSFP) and 1.58 ± 0.20 (T2‐prepared bSSFP); the theoretically estimated relative relaxation and M0 effects were: 1.17 ± 0.09 and 1.30 ± 0.19, respectively (cine bSSFP), and 1.49 ± 0.23 and 1.06 ± 0.07, respectively (T2‐prepared bSSFP). There were no significant difference between cine bSSFP and T2‐prep bSSFP relative signal‐intensity ratios. However, the relative relaxation effect in cine bSSFP was significantly lower than in T2‐prep bSSFP (P < 0.05), and the M0 effect in cine bSSFP was significantly higher than in T2‐prep bSSFP (P < 0.05). Hence the acquisition strategies that wish to maximize myocardial edema contrast in cine bSSFP imaging should take both relaxation and M0 effects into account. Magn Reson Med, 2011.Keywords
Funding Information
- National Institute of Health Grants (NHLBI HL091989)
This publication has 13 references indexed in Scilit:
- Myocardial edema contrast in acute myocardial infarction: a comparative study of the sensitivity of different CMR MethodsJournal of Cardiovascular Magnetic Resonance, 2010
- Balanced steady-state free precession cardiovascular magnetic resonance imaging of edema in reperfused acute myocardial infarcts - a translational study in animals and menJournal of Cardiovascular Magnetic Resonance, 2010
- Assessment of magnetization transfer effects in myocardial tissue using balanced steady‐state free precession (bSSFP) cine MRIMagnetic Resonance in Medicine, 2009
- T2 quantification for improved detection of myocardial edemaJournal of Cardiovascular Magnetic Resonance, 2009
- Optimization and validation of a fully‐integrated pulse sequence for modified look‐locker inversion‐recovery (MOLLI) T1 mapping of the heartJournal of Magnetic Resonance Imaging, 2007
- T2‐prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echoMagnetic Resonance in Medicine, 2007
- T2-prepared Steady-State Free Precession Blood Oxygen Level–Dependent MR Imaging of Myocardial Perfusion in a Dog Stenosis ModelRadiology, 2005
- K‐space in the clinicJournal of Magnetic Resonance Imaging, 2004
- T1 quantification with inversion recovery TrueFISPMagnetic Resonance in Medicine, 2001
- "Black blood" T2-weighted inversion-recovery MR imaging of the heart.Radiology, 1996