Randomized, single blinded control trial comparing haemolysis rate between two cannula aspiration techniques
- 1 October 2006
- journal article
- research article
- Published by Wiley in Emergency Medicine Australasia
- Vol. 18 (5-6) , 484-488
Abstract
Objective: Blood aspiration through i.v. cannulae is a common ED sampling method. It is, however, associated with increased haemolysis rates when compared with direct venipuncture. Our ED utilizes two common methods of sampling through cannulae. The aim of the present study was to examine the haemolysis rates for these two techniques.Methods: A randomized, single blinded prospective study was performed. From a convenience sample patients were randomized to either ‘Method one’ (blood taken directly from cannula hub) or ‘Method two’ (blood taken using an Interlink device through cannula cap). For each group patient demographics, clinical information and haemolysis were analysed. χ2‐analysis and a multivariate logistic regression model were applied to determine significant relationships.Results: A total of 1390 patients were enrolled, 694 had blood collected by ‘Method one’ and 696 by ‘Method two’, with haemolysis rates of 6.5% and 7.2%, respectively. Univariate analysis showed ease of aspiration to be the only variable to have a strong association with haemolysis (P < 0.0001). After allowing for ease of aspiration the technique used did not significantly affect haemolysis rate (P = 0.7).Conclusions: The rate of haemolysis is unrelated to the technique of blood aspiration. However, haemolysis rates increase significantly with perceived difficulty of blood draw.Keywords
This publication has 8 references indexed in Scilit:
- Factors Affecting the Risk of Blood Bank Specimen HemolysisAcademic Emergency Medicine, 2003
- The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samplesJournal of Emergency Nursing, 2003
- Hemolysis in Serum Samples Drawn by Emergency Department Personnel versus Laboratory PhlebotomistsLaboratory Medicine, 2002
- The effect of the InterLinkR cannula on fluid flow rates and haemolysisEmergency Medicine Australasia, 2001
- Accuracy of drawing blood through infusing intravenous linesHeart & Lung, 2001
- A comparative study of hematocrits drawn from a standard venipuncture and those drawn from a saline lock deviceJournal of Emergency Nursing, 1997
- A comparison of hemolysis rates using intravenous catheters versus venipuncture tubes for obtaining blood samplesJournal of Emergency Nursing, 1996
- Hemolysis of blood specimens transported from ED to laboratory by pneumatic tubeThe American Journal of Emergency Medicine, 1995