Nephron blood flow dynamics measured by laser speckle contrast imaging
- 1 February 2011
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Renal Physiology
- Vol. 300 (2) , F319-F329
Abstract
Tubuloglomerular feedback (TGF) has an important role in autoregulation of renal blood flow and glomerular filtration rate (GFR). Because of the characteristics of signal transmission in the feedback loop, the TGF undergoes self-sustained oscillations in single-nephron blood flow, GFR, and tubular pressure and flow. Nephrons interact by exchanging electrical signals conducted electrotonically through cells of the vascular wall, leading to synchronization of the TGF-mediated oscillations. Experimental studies of these interactions have been limited to observations on two or at most three nephrons simultaneously. The interacting nephron fields are likely to be more extensive. We have turned to laser speckle contrast imaging to measure the blood flow dynamics of 50–100 nephrons simultaneously on the renal surface of anesthetized rats. We report the application of this method and describe analytic techniques for extracting the desired data and for examining them for evidence of nephron synchronization. Synchronized TGF oscillations were detected in pairs or triplets of nephrons. The amplitude and the frequency of the oscillations changed with time, as did the patterns of synchronization. Synchronization may take place among nephrons not immediately adjacent on the surface of the kidney.Keywords
This publication has 46 references indexed in Scilit:
- Coupling-induced complexity in nephron models of renal blood flow regulationAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2010
- Laser speckle contrast imaging in biomedical opticsJournal of Biomedical Optics, 2010
- Speckle Tracking Ultrasound for Assessment of the Relative Motion of Flexor Tendon and Subsynovial Connective Tissue in the Human Carpal TunnelUltrasound in Medicine & Biology, 2009
- Electrotonic vascular signal conduction and nephron synchronizationAmerican Journal of Physiology-Renal Physiology, 2009
- Analysis of nonstationarity in renal autoregulation mechanisms using time-varying transfer and coherence functionsAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2008
- Vascular coupling induces synchronization, quasiperiodicity, and chaos in a nephron treeChaos: An Interdisciplinary Journal of Nonlinear Science, 2007
- A comparison of two laser-based methods for determination of burn scar perfusion: Laser Doppler versus laser speckle imagingBurns, 2005
- Modified laser speckle imaging method with improved spatial resolutionJournal of Biomedical Optics, 2003
- A laser Doppler instrument for in vivo measurements of blood flow in single renal arteriolesIEEE Transactions on Biomedical Engineering, 1993
- TGF‐mediated oscillations in the proximal intratubular pressure: differences between spontaneously hypertensive rats and Wistar‐Kyoto ratsActa Physiologica Scandinavica, 1986