High validity of measuring the width and volume of medial meniscal extrusion three‐dimensionally using an MRI‐derived tibial model
Open Access
- 3 January 2020
- journal article
- research article
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 7 (1) , 1-10
Abstract
Background: Medial meniscal extrusion (MME) is an important marker of knee osteoarthritis (KOA) progression. The purposes of this study were: 1) to determine whether there are morphological differences between CT‐ and MRI‐derived tibial plateau models; and 2) to determine whether measurement of MME volume and width using an MRI‐derived tibial model is as accurate as measurements on a CT‐derived tibial model.Methods: This was a cross‐sectional study that enrolled ten participants with medial KOA (Kellgren‐Lawrence grade 1 to 3). Primary outcome was surface difference of the medial tibial plateau between CT‐ and MRI‐derived models. Furthermore, volume and cross‐sectional area of the medial tibial plateau were compared between CT‐ and MRI‐derived models. Measurements of MME volume and width were compared between CT‐ and MRI‐derived tibial models.Results: Minimal and maximal surface differences of the medial tibial plateau between the CT‐ and MRI‐derived models were − 0.15 [− 0.44, 0.14] mm (mean [95% confidence interval]) and 0.24 [− 0.09, 0.57] mm, respectively. There were no significant differences in volume and cross‐sectional area of the medial tibial plateau between CT‐ and MRI‐derived tibial models. The MME volumes measured on CT‐ and MRI‐derived models were 942.6 [597.7, 1287.6] mm3 and 916.2 [557.9, 1274.6] mm3, respectively (p = 0.938). The MME widths measured on CT‐ and MRI‐derived models were 4.2 [1.9, 6.5] mm and 4.5 [2.2, 6.9] mm, respectively (p = 0.967).Conclusions: CT‐ and MRI‐derived models of the medial tibial plateau did not show significant morphological differences. Both CT‐ and MRI‐derived tibia can be used as a reference to measure MME in early‐to‐moderate medial KOA.Keywords
This publication has 22 references indexed in Scilit:
- Quantification of the accuracy of MRI generated 3D models of long bones compared to CT generated 3D modelsMedical Engineering & Physics, 2011
- Kinematics of medial osteoarthritic knees before and after posterior cruciate ligament retaining total knee arthroplastyJournal of Orthopaedic Research, 2010
- Proximal tibial osteophytes and their relationship with the height of the tibial spines of the intercondylar eminence: paleopathological studySkeletal Radiology, 2009
- Tibiofemoral Joint Osteoarthritis: Risk Factors for MR-depicted Fast Cartilage Loss over a 30-month Period in the Multicenter Osteoarthritis StudyRadiology, 2009
- Accuracy of MRI vs CT imaging with particular reference to patient specific templates for total knee replacement surgeryThe International Journal of Medical Robotics and Computer Assisted Surgery, 2008
- Accuracy assessment of CT-based outer surface femur meshesComputer Aided Surgery, 2008
- Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysisBone, 2007
- Can magnetic resonance imaging–derived bone models be used for accurate motion measurement with single‐plane three‐dimensional shape registration?Journal of Orthopaedic Research, 2007
- The association of meniscal pathologic changes with cartilage loss in symptomatic knee osteoarthritisArthritis & Rheumatism, 2006
- Characterisation of size and direction of osteophyte in knee osteoarthritis: a radiographic studyAnnals of the Rheumatic Diseases, 2002