Evaluation of bone metastatic burden by bone SPECT/CT in metastatic prostate cancer patients: defining threshold value for total bone uptake and assessment in radium-223 treated patients
Authors:
Open Access
- 14 December 2017
- journal article
- research article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 32 (2) , 105-113
Abstract
Objectives To establish a new three-dimensional quantitative evaluation method for bone metastasis, we applied bone single photon emission tomography with computed tomography (SPECT/CT). The total bone uptake (TBU), which measures active bone metastatic burden, was calculated as the sum of [mean uptake obtained as standardized uptake value (SUV) above a cut-off level] × (the volume of the lesion) in the trunk using bone SPECT/CT. We studied the threshold value and utility of TBU in prostate cancer patients treated with radium-223 (Ra-223) therapy. Methods To establish the threshold value of TBU, we compared bone metastatic and non-metastatic regions in 61 prostate cancer patients with bone metastasis and 69 without. Five fixed sites in each patient were selected as evaluation points and divided into bone metastatic and non-metastatic sites. Sensitivity and specificity analysis was applied to establish the threshold level. Using the obtained threshold value, we then calculated the TBU in nine prostate cancer patients who received Ra-223 therapy, and compared the results with the bone scan index (BSI) by BONENAVI® and visual evaluation of bone scintigraphy. Results Uptake was significantly lower in non-metastatic sites in patients with bone metastasis than in patients without metastasis. Sensitivity and specificity analysis revealed SUV = 7.0 as the threshold level. There was a discrepancy between TBU and BSI change in two of the nine patients, in whom TBU change correlated with visual judgement, but BSI change did not. In two patients, BSI was nearly 0 throughout the course, but the TBU was positive and changed, although the change was not large. These results suggest that TBU may be more accurate and sensitive than BSI for quantitative evaluation of active bone metastatic burden. Conclusion We established a threshold value (SUV > 7.0) for three-dimensional TBU for evaluating active bone metastatic burden in prostate cancer patients using bone SPECT/CT. Despite the small number of patients, we expect the change in TBU could be more accurate and sensitive than the change in BSI among patients who received Ra-223.Keywords
This publication has 26 references indexed in Scilit:
- Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modalityEuropean Journal of Nuclear Medicine and Molecular Imaging, 2013
- Alpha Emitter Radium-223 and Survival in Metastatic Prostate CancerNew England Journal of Medicine, 2013
- An Evidence-Based Review of Quantitative SPECT Imaging and Potential Clinical ApplicationsJournal of Nuclear Medicine, 2013
- Quantification of 99mTc-DPD concentration in the lumbar spine with SPECT/CTEJNMMI Research, 2013
- Prediction of survival benefit using an automated bone scan index in patients with castration‐resistant prostate cancerBJU International, 2012
- Bone Scan Index: A Quantitative Treatment Response Biomarker for Castration-Resistant Metastatic Prostate CancerJournal of Clinical Oncology, 2012
- Quantitative Accuracy of Clinical 99mTc SPECT/CT Using Ordered-Subset Expectation Maximization with 3-Dimensional Resolution Recovery, Attenuation, and Scatter CorrectionJournal of Nuclear Medicine, 2010
- New response evaluation criteria in solid tumours: Revised RECIST guideline (version 1.1)European Journal of Cancer, 2009
- Computer-Assisted Interpretation of Planar Whole-Body Bone ScansJournal of Nuclear Medicine, 2008
- Understanding diagnostic tests 3: receiver operating characteristic curvesActa Paediatrica, 2007