Pre-analytical and analytical variables that influence urinary volatile organic compound measurements
Open Access
- 31 July 2020
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (7) , e0236591
Abstract
There has been rapidly accelerating interest in the utilization of volatile organic compounds (VOCs) as non-invasive methods for rapid point-of-care medical diagnostics. There is widespread variation in analytical methods and protocols, with little understanding of the effects of sample storage on VOC profiles. This study aimed to determine the effects on VOC profiles of different storage times, at room temperature, prior to freezing, of sealed urine samples from healthy individuals. Analysis using Field Asymmetric Ion Motility Spectrometry (FAIMS) determined the alterations in VOC and total ion count profiles as a result of increasing room temperature storage times. Results indicated that increasing exposure time to room temperature prior to freezing had a threefold effect. Firstly, increased urinary VOC profile variability, with a plateau phase between 12 and 48 hours, before further degradation. Secondly, an increase in total ion count with time exposed to room temperature. Finally, a deterioration in VOCs with each sample run during the analysis process. This provides new insight into the effect of storage of urine samples for VOC analysis using FAIMS technology. Results of this study provide a recommendation for a 12-hour maximum duration at room temperature prior to storage.Keywords
This publication has 27 references indexed in Scilit:
- Changes in volatile compounds of human urine as it ages: Their interaction with waterJournal of Chromatography B, 2013
- Application of a Novel Tool for Diagnosing Bile Acid DiarrhoeaSensors, 2013
- Changes in volatile compounds of mouse urine as it ages: Their interactions with water and urinary proteinsPhysiology & Behavior, 2013
- A Novel Tool for Noninvasive Diagnosis and Tracking of Patients with Inflammatory Bowel DiseaseInflammatory Bowel Diseases, 2013
- The Electronic Nose in Respiratory MedicineRespiration, 2012
- Detection and identification of cancers by the electronic noseExpert Opinion on Medical Diagnostics, 2012
- Advances in Electronic-Nose Technologies Developed for Biomedical ApplicationsSensors, 2011
- Liquid chromatography and ultra-performance liquid chromatography–mass spectrometry fingerprinting of human urineJournal of Chromatography A, 2008
- A GC-TOF-MS study of the stability of serum and urine metabolomes during the UK Biobank sample collection and preparation protocolsInternational Journal of Epidemiology, 2008
- Urine stability for metabolomic studies: effects of preparation and storageMetabolomics, 2007