Video‐Assisted Endoscopic Removal of Infected Endocardial Pacemaker Lead with Large Floating Vegetation
Authors:
- 1 November 1999
- journal article
- case report
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 22 (11) , 1700-1703
Abstract
The best management of pacemaker lead related endocarditis is complete surgical or percutaneous removal of the pacemaker system. Although the traditional surgical approach is via median sternotomy, we present two cases in which the lead and vegetations were removed using a video‐assisted endoscopic technique through a limited right submammary incision. In each case the patient was supported by partial extracorporeal perfusion. Additional tricuspid valve repair and atrial septal defect closure was performed in one case. The postoperative courses were uneventful, illustrating that, when compared to the conventional open heart surgical approach, the less invasive approach can be a safe and effective way to remove an infected foreign body from the right heart with increased comfort, fast recovery, and a better cosmetic result.Keywords
This publication has 7 references indexed in Scilit:
- Cardiac Pacemaker Infection: Surgical Management With and Without Extracorporeal CirculationThe Annals of Thoracic Surgery, 1997
- Video-Assisted Thoracic Surgery: Has Technology Found its Place?The Annals of Thoracic Surgery, 1997
- Systemic Infection Related to Endocarditis on Pacemaker LeadsCirculation, 1997
- Minimally invasive mitral valve operationsThe Annals of Thoracic Surgery, 1996
- Video-Assisted Cardiac Surgery in Closure of Atrial Septal DefectThe Annals of Thoracic Surgery, 1996
- Surgical treatment of prosthetic valve endocarditisThe Journal of Thoracic and Cardiovascular Surgery, 1996
- Five‐Years Experience with Intravascular Lead ExtractionPacing and Clinical Electrophysiology, 1994