Single‐sweep pulmonary vein isolation using the new third‐generation laser balloon—Evolution in ablation style using endoscopic ablation system
- 17 September 2021
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 32 (11) , 2923-2932
Abstract
Background: The endoscopic ablation system (EAS) is an established ablation device for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). The novel X3 EAS is now equipped with a contiguous circumferential ablation mode (RAPID mode).Aim: To determine the feasibility of single‐shot fashioned ablation using X3.Methods: Consecutive patients who underwent AF ablation using X3 were enrolled. We assessed the acute procedural data focusing on “Single‐sweep PVI” defined as successful PVI with a single RAPID mode energy application, and on “first‐pass isolation” defined as successful PVI after initial circular lesion set.Results: One hundred AF patients (56% male, age: 68 ± 10 years, 66% paroxysmal AF) were analyzed. A total of 379 of 383 PVs (99%) were isolated with X3. Single‐sweep PVI and first‐pass‐isolation were achieved in 214 PVs (56%) and in 362 PVs (95%), respectively. Single‐sweep PVI rates varied across PVs with higher rates at the superior PVs (61.2% vs. inferior PVs: 49.5%, p = .0239) and at PVs with maximal ostial diameter 24 mm: 36.8%, p = .0151). The mean total procedure and fluoroscopy times were 43.0 ± 10 and 4.0 ± 2 min, respectively. In none of the patients an acute thromboembolic event (stroke or transient ischemic attack) or a pericardial effusion/tamponade occurred. A single transient phrenic nerve palsy was observed.Conclusion: The new X3 EAS allows for single‐shot fashioned ablation in terms of single‐sweep PVI in half or more of PVs. The new RAPID ablation mode leads to an improved rate of first‐pass isolation associated with very short procedure times without compromising safety.Keywords
All Related Versions
This publication has 19 references indexed in Scilit:
- Use of Ablation Index-Guided Ablation Results in High Rates of Durable Pulmonary Vein Isolation and Freedom From Arrhythmia in Persistent Atrial Fibrillation PatientsCirculation: Arrhythmia and Electrophysiology, 2018
- A RAndomized Trial to compare the acute reconnection after pulmonary vein ISolation with Laser‐BalloON versus radiofrequency Ablation: RATISBONA trialJournal of Cardiovascular Electrophysiology, 2018
- Laser Balloon or Wide-Area Circumferential Irrigated Radiofrequency Ablation for Persistent Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2017
- Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial FibrillationNew England Journal of Medicine, 2016
- Pulmonary Vein Isolation Using the Visually Guided Laser BalloonJACC, 2015
- Visually guided laser ablation: a single-centre long-term experienceEP Europace, 2014
- Endoscopic ablation systemsExpert Review of Medical Devices, 2013
- The influence of varying energy settings on efficacy and safety of endoscopic pulmonary vein isolationHeart Rhythm, 2012
- Visually Guided Sequential Pulmonary Vein Isolation: Insights into Techniques and Predictors of Acute SuccessJournal of Cardiovascular Electrophysiology, 2012
- Esophageal temperature change and esophageal thermal lesions after pulmonary vein isolation using the novel endoscopic ablation systemHeart Rhythm, 2011