On the impact of dose rate variation upon RapidArc® implementation of volumetric modulated arc therapy
Authors:
- Giorgia NicoliniGNGiorgia Nicolini
- Alessandro ClivioACAlessandro Clivio
- Luca CozziLCLuca Cozzi
- Antonella FogliataAFAntonella Fogliata
- Eugenio VanettiEVEugenio Vanetti
- 20 December 2010
- journal article
- Published by Wiley in Medical Physics
- Vol. 38 (1) , 264-271
Abstract
Purpose: A study was carried out to evaluate the robustness and mutual interplay of two variables concurring to generate modulation patterns of the RapidArc® (RapidArc) implementation of volumetric modulated arc therapy. Dose rate (DR) and gantry speed (GS) are free parameters optimized alongside field aperture shape by the RapidArc engine; however, they are limited by machine constraints and mutually compensate in order to deliver the proper MU/deg during the gantry rotation.Methods: Four test cases (one geometrical and three clinical) were selected and RapidArc plans were optimized using maximum allowed dose rates from 100 to 600 MU/min. The maximum gantry speed was fixed at 4.8 deg/s. Qualitative analysis of DR and GS patterns from these cases was summarized together with quantitative assessment of delivery parameters. Pretreatment quality assurance measurements and scoring of plan quality aimed to determine whether preferable initial conditions might be identified or the optimization engine might be invariant to those variables and capable of providing adequate plans independently from the limits applied.Results: The results of the study were: (i) High dynamic range in MU/deg is achievable across all dose rates by means of gantry speed modulation; (ii) there is a robust compensation mechanism between the two variables; (iii) from a machine delivery point‐of‐view, slightly improved accuracy is achieved when lower DRs are applied; however, this does not have practical consequences since measurements and plan evaluation showed a lack of clinically relevant deviation; and (iv) reduced total treatment time is a major advantage of high DR.Conclusions: A trend toward improved plan quality for clinical cases was observed with high DR but cannot be generalized, due to the limited amount of cases investigated and the consequent limited significance of the observed differences. As a minimum benefit, the reduced total treatment time should be considered as well.Keywords
This publication has 23 references indexed in Scilit:
- Pre-clinical evaluation of respiratory-gated delivery of volumetric modulated arc therapy with RapidArcPhysics in Medicine & Biology, 2010
- Radiotherapy Treatment Plans With RapidArc for Prostate Cancer Involving Seminal Vesicles and Lymph NodesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity-modulated arcsRadiotherapy and Oncology, 2009
- Volumetric-modulated arc radiotherapy for carcinomas of the anal canal: A treatment planning comparison with fixed field IMRTRadiotherapy and Oncology, 2009
- Volumetric Modulated Arc Radiotherapy for Vestibular SchwannomasInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Volumetric Intensity-Modulated Arc Therapy Vs. Conventional IMRT in Head-and-Neck Cancer: A Comparative Planning and Dosimetric StudyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Letter to the Editor on ‘Single-Arc IMRT?’Physics in Medicine & Biology, 2009
- RapidArc volumetric modulated therapy planning for prostate cancer patientsActa Oncologica, 2009
- A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations*Physics in Medicine & Biology, 2005
- Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapyPhysics in Medicine & Biology, 1995