Performance Investigation of a Two-Bed Type Adsorption Chiller with Various Adsorbents
Open Access
Abstract
In this study, the performance evaluation of an adsorption chiller (AD) system with three different adsorbents—silica-gel, aluminum fumarate, and FAM-Z01—was conducted to investigate the effects of adsorption isotherms and physical properties on the system’s performance. In addition, the performance evaluation of the AD system for a low inlet hot-water temperature of 60 °C was performed to estimate the performance of the system when operated by low quality waste heat or sustainable energy sources. For the simulation work, a two-bed type AD system is considered, and silica-gel, metal organic frameworks (MOFs), and ferro-aluminophosphate (FAPO, FAM-Z01) were employed as adsorbents. The simulation results were well matched with the laboratory-scale experimental results and the maximum coefficient of performance (COP) difference was 7%. The cooling capacity and COP of the AD system were investigated at different operating conditions to discuss the influences of the adsorbents on the system performance. Through this study, the excellence of the adsorbent, which has an S-shaped isotherm graph, was presented. In addition, the influences of the physical properties of the adsorbent were also discussed with reference to the system performance. Among the three different adsorbents employed in the AD system, the FAM-Z01 shows the best performance at inlet hot water temperature of 60 °C, which can be obtained from waste heat or sustainable energy, where the cooling capacity and COP were 5.13 kW and 0.47, respectively.Keywords
Funding Information
- Korea Institute of Energy Technology Evaluation and Planning (No. 20192050100070)
This publication has 27 references indexed in Scilit:
- Experimental investigation on the optimal performance of Zeolite–water adsorption chillerApplied Energy, 2013
- Experimental testing of a lab-scale adsorption chiller using a novel selective water sorbent “silica modified by calcium nitrate”International Journal of Refrigeration, 2012
- Physical and operating conditions effects on silica gel/water adsorption chiller performanceApplied Energy, 2012
- Study on a compact silica gel–water adsorption chiller without vacuum valves: Design and experimental studyApplied Energy, 2010
- Design and performance of a solar-powered heating and cooling system using silica gel/water adsorption chillerApplied Thermal Engineering, 2009
- Theoretical research of a silica gel–water adsorption chiller in a micro combined cooling, heating and power (CCHP) systemApplied Energy, 2009
- Study of a novel silica gel–water adsorption chiller. Part II. Experimental studyInternational Journal of Refrigeration, 2005
- Study of a novel silica gel–water adsorption chiller. Part I. Design and performance predictionInternational Journal of Refrigeration, 2005
- Transient modeling of a two-bed silica gel–water adsorption chillerInternational Journal of Heat and Mass Transfer, 2004
- Experimental investigation of the silica gel–water adsorption isotherm characteristicsApplied Thermal Engineering, 2001